About: New approach for measuring the angle of hallux valgus     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Since only the medium correlation between current anthropometric and radiographic way in measuring angle of hallux valgus (AoH) was reported, this study first aimed at designing a new way to measure the AoH (AoHnew) and then evaluating its reliability and validity. Method: Fifteen ages-, body weightand height-matched male students were recruited and those with foot disorders, deformities or injuries were excluded. The dorsal protrusion of the first metatarsal head (MTH) and base (MTB) and hallux were marked by palpating from one experienced observer. Then their barefoot model in standing was collected by a three dimensional laser scanning system. The AoHnew was defined in X-Y plane as the angle between the line joining the marks of MTH and MTB and the line connecting the marks of MTH and hallux. Another session was measured one week later. Other measures based on the way of footprint, outline and radiography were also available for comparisons. Paired-T test, linear regression and reliability analysis were applied for statistical analysis with significant level of 0.05 and 95% confidence interval. The results show that no significant differences were recorded between the new method and radiographic way (p=0.069). The AoHnew was superior to the methods of foot print and outline and it presented a relative higher linear correlation coefficiency (r=0.94, r2=0.89) with radiographic way. Moreover the result of new method was proved to be reliable (CoV=9.2%, ICC =0.940). Conclusion: This new method could be used for hallux valgus inspection and diagnosis.
  • Since only the medium correlation between current anthropometric and radiographic way in measuring angle of hallux valgus (AoH) was reported, this study first aimed at designing a new way to measure the AoH (AoHnew) and then evaluating its reliability and validity. Method: Fifteen ages-, body weightand height-matched male students were recruited and those with foot disorders, deformities or injuries were excluded. The dorsal protrusion of the first metatarsal head (MTH) and base (MTB) and hallux were marked by palpating from one experienced observer. Then their barefoot model in standing was collected by a three dimensional laser scanning system. The AoHnew was defined in X-Y plane as the angle between the line joining the marks of MTH and MTB and the line connecting the marks of MTH and hallux. Another session was measured one week later. Other measures based on the way of footprint, outline and radiography were also available for comparisons. Paired-T test, linear regression and reliability analysis were applied for statistical analysis with significant level of 0.05 and 95% confidence interval. The results show that no significant differences were recorded between the new method and radiographic way (p=0.069). The AoHnew was superior to the methods of foot print and outline and it presented a relative higher linear correlation coefficiency (r=0.94, r2=0.89) with radiographic way. Moreover the result of new method was proved to be reliable (CoV=9.2%, ICC =0.940). Conclusion: This new method could be used for hallux valgus inspection and diagnosis. (en)
Title
  • New approach for measuring the angle of hallux valgus
  • New approach for measuring the angle of hallux valgus (en)
skos:prefLabel
  • New approach for measuring the angle of hallux valgus
  • New approach for measuring the angle of hallux valgus (en)
skos:notation
  • RIV/70883521:28110/12:43869058!RIV13-MSM-28110___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • V
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 153958
http://linked.open...ai/riv/idVysledku
  • RIV/70883521:28110/12:43869058
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • three dimensional laser feet scanning; foot print; angle of hallux; hallux valgus; Radiography (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [637EC1C43426]
http://linked.open...v/mistoKonaniAkce
  • Zlín
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • Advances in Environment, Biotechnology and Biomedicine
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Hlaváček, Petr
  • Chen, Wuyong
  • Zhou, Jin
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • WSEAS Press
https://schema.org/isbn
  • 978-1-61804-122-7
http://localhost/t...ganizacniJednotka
  • 28110
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software