About: Study of edgeless radiation detector with 3D spatial mapping technique     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Edgeless radiation detector has gained increased attention due to its superiority in the defect-free edge fabrication and the capability to minimize the insensitive area at the detector edge. The doped edge in the edgeless detector is at the same potential with the back plane and causes a local distortion of the electric field at the detector edge. The deformed electric field alters the charge collection of the edge pixel and leads to an inaccurate charge interpolation. To study the influence of active edges on the response of edge pixels, we used an advanced X-ray based 3D spatial mapping technique to visually show the charge collection volumes of pixels. Various edgeless detectors with diverse polarities, thicknesses and edge-to-pixel distances were investigated. For the n-on-p (n+/p-/p+) edgeless detector, the mapping shows that the p-spray isolation method has the advantage of achieving a greater sensitive edge region compared to the p-stop method. And the p-on-p (p+/p-/n+) edgeless detector, reported for the first time, functions for both spatial and energy signals. The n-type edgeless detectors were studied together with a standard Medipix detector with the guard ring design. The results show that the edgeless detector is capable of maximally utilizing the edge region of the detector as the charge sensitive volume, while the standard Medipix detector has still vast insensitive region at the edge. The X-ray spectroscopic measurements with 241Am and 55Fe sources performed on all detectors gives a similar conclusion and proves the 3D spatial mapping results.
  • Edgeless radiation detector has gained increased attention due to its superiority in the defect-free edge fabrication and the capability to minimize the insensitive area at the detector edge. The doped edge in the edgeless detector is at the same potential with the back plane and causes a local distortion of the electric field at the detector edge. The deformed electric field alters the charge collection of the edge pixel and leads to an inaccurate charge interpolation. To study the influence of active edges on the response of edge pixels, we used an advanced X-ray based 3D spatial mapping technique to visually show the charge collection volumes of pixels. Various edgeless detectors with diverse polarities, thicknesses and edge-to-pixel distances were investigated. For the n-on-p (n+/p-/p+) edgeless detector, the mapping shows that the p-spray isolation method has the advantage of achieving a greater sensitive edge region compared to the p-stop method. And the p-on-p (p+/p-/n+) edgeless detector, reported for the first time, functions for both spatial and energy signals. The n-type edgeless detectors were studied together with a standard Medipix detector with the guard ring design. The results show that the edgeless detector is capable of maximally utilizing the edge region of the detector as the charge sensitive volume, while the standard Medipix detector has still vast insensitive region at the edge. The X-ray spectroscopic measurements with 241Am and 55Fe sources performed on all detectors gives a similar conclusion and proves the 3D spatial mapping results. (en)
Title
  • Study of edgeless radiation detector with 3D spatial mapping technique
  • Study of edgeless radiation detector with 3D spatial mapping technique (en)
skos:prefLabel
  • Study of edgeless radiation detector with 3D spatial mapping technique
  • Study of edgeless radiation detector with 3D spatial mapping technique (en)
skos:notation
  • RIV/68407700:21670/14:00229059!RIV15-TA0-21670___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(TA01010237)
http://linked.open...iv/cisloPeriodika
  • 9
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 48259
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21670/14:00229059
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Solid state detectors; Particle tracking detectors; X-ray detectors (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • IT - Italská republika
http://linked.open...ontrolniKodProRIV
  • [F9A5095E5817]
http://linked.open...i/riv/nazevZdroje
  • Journal of Instrumentation
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 9
http://linked.open...iv/tvurceVysledku
  • Jakůbek, Jan
  • Kalliopuska, J.
  • Jakůbek, Martin
  • Wu, X.
  • Eranen, S.
  • Gadda, A.
http://linked.open...ain/vavai/riv/wos
  • 000336123800004
issn
  • 1748-0221
number of pages
http://bibframe.org/vocab/doi
  • 10.1088/1748-0221/9/04/C04004
http://localhost/t...ganizacniJednotka
  • 21670
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software