AttributesValues
rdf:type
Description
  • The aim of this study is to determine constitutive constants for elasto-plastic material model with damage for single trabecula based on the indirect simulation of micromechanical testing and its verification at macro level using compression test of the cylindrical sample of the trabecular tissue. Three-point bending test of isolated trabeculae was performed in a shielding box and deflection of the sample was acquired using X-ray microradiography. Measured values (displacements of markers) were used for indirect identification of the material model for single trabecula using finite element (FE) method. The bending test was simulated and results were fitted to experimentally obtained values and the appropriate set of material constants was determined. To verify the applicability of the identified material model the compression test of the complex sample was carried out. Cylindrical sample was incrementally loaded and each loading state was captured using the micro-computed tomography. Material model identified from three-point bending test was applied to the model of complex sample and the simulation of the compression test was performed.
  • The aim of this study is to determine constitutive constants for elasto-plastic material model with damage for single trabecula based on the indirect simulation of micromechanical testing and its verification at macro level using compression test of the cylindrical sample of the trabecular tissue. Three-point bending test of isolated trabeculae was performed in a shielding box and deflection of the sample was acquired using X-ray microradiography. Measured values (displacements of markers) were used for indirect identification of the material model for single trabecula using finite element (FE) method. The bending test was simulated and results were fitted to experimentally obtained values and the appropriate set of material constants was determined. To verify the applicability of the identified material model the compression test of the complex sample was carried out. Cylindrical sample was incrementally loaded and each loading state was captured using the micro-computed tomography. Material model identified from three-point bending test was applied to the model of complex sample and the simulation of the compression test was performed. (en)
Title
  • Verification of Numerical Model for Trabecular Tissue using Compression Test and Time-Lapse X-Ray Radiography based on Material Model Determined from Three-Point Bending Test of Single Trabecula
  • Verification of Numerical Model for Trabecular Tissue using Compression Test and Time-Lapse X-Ray Radiography based on Material Model Determined from Three-Point Bending Test of Single Trabecula (en)
skos:prefLabel
  • Verification of Numerical Model for Trabecular Tissue using Compression Test and Time-Lapse X-Ray Radiography based on Material Model Determined from Three-Point Bending Test of Single Trabecula
  • Verification of Numerical Model for Trabecular Tissue using Compression Test and Time-Lapse X-Ray Radiography based on Material Model Determined from Three-Point Bending Test of Single Trabecula (en)
skos:notation
  • RIV/68407700:21670/14:00208101!RIV15-MSM-21670___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GAP105/10/2305), S, Z(MSM6840770040), Z(MSM6840770043)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 53240
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21670/14:00208101
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • compression test; FEM; radiography; three-point bending; trabecular bone (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [42C97B9F07FC]
http://linked.open...v/mistoKonaniAkce
  • Levoča
http://linked.open...i/riv/mistoVydani
  • Zürich
http://linked.open...i/riv/nazevZdroje
  • 9th International Conference on Local Mechanical Properties
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Doktor, Tomáš
  • Jiroušek, Ondřej
  • Zlámal, Petr
  • Jandejsek, Ivan
http://linked.open...vavai/riv/typAkce
http://linked.open...ain/vavai/riv/wos
  • 000336633500065
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
issn
  • 1013-9826
number of pages
http://bibframe.org/vocab/doi
  • 10.4028/www.scientific.net/KEM.586.265
http://purl.org/ne...btex#hasPublisher
  • Transtech Publications
https://schema.org/isbn
  • 978-3-03785-876-9
http://localhost/t...ganizacniJednotka
  • 21670
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 49 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software