About: Application of the Medipix2 technology to space radiation dosimetry and hadron therapy beam monitoring     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The Medipix2 Collaboration, based at CERN, has developed the TimePix version of the Medipix pixel readout chip, which has the ability to provide either an ADC or TDC capability separately in each of its 256 x 256 pixels. When coupled to a Si detector layer, the device is an excellent candidate for application as an active dosimeter for use in Space Radiation Environments. In order to facilitate such a development, data have been taken with Heavy Ions at the HIMAC facility in Chiba, Japan. In particular, the problem of determining the resolution of such a detector system with respect to heavy ions of differing charges and energies, but with similar dE/dx values has been explored for several ions. The ultimate problem is to parse the information in the pixel %22footprint%22 images from the drift of the charge-cloud produced in the detector layer. In addition, with the use of convertor materials, the detector can be used as a neutron detector, and it has been used both as a charged particle and neutron detector to evaluate the detailed properties of the radiation fields produced by hadron therapy beams. The first space flight of a Medipix-based detector is currently planned for the first quarter of 2012 onboard the UK TechDemoSat-1 satellite as part of the LUCID project. The instrument to be flown is currently planned to have 5 TimePix versions of the Medipix2 detector deployed on 5 of the 6 faces of a cube with similar to 3 cm on each side and enclosed by a 0.7 mm thick Al cylindrical cover.
  • The Medipix2 Collaboration, based at CERN, has developed the TimePix version of the Medipix pixel readout chip, which has the ability to provide either an ADC or TDC capability separately in each of its 256 x 256 pixels. When coupled to a Si detector layer, the device is an excellent candidate for application as an active dosimeter for use in Space Radiation Environments. In order to facilitate such a development, data have been taken with Heavy Ions at the HIMAC facility in Chiba, Japan. In particular, the problem of determining the resolution of such a detector system with respect to heavy ions of differing charges and energies, but with similar dE/dx values has been explored for several ions. The ultimate problem is to parse the information in the pixel %22footprint%22 images from the drift of the charge-cloud produced in the detector layer. In addition, with the use of convertor materials, the detector can be used as a neutron detector, and it has been used both as a charged particle and neutron detector to evaluate the detailed properties of the radiation fields produced by hadron therapy beams. The first space flight of a Medipix-based detector is currently planned for the first quarter of 2012 onboard the UK TechDemoSat-1 satellite as part of the LUCID project. The instrument to be flown is currently planned to have 5 TimePix versions of the Medipix2 detector deployed on 5 of the 6 faces of a cube with similar to 3 cm on each side and enclosed by a 0.7 mm thick Al cylindrical cover. (en)
Title
  • Application of the Medipix2 technology to space radiation dosimetry and hadron therapy beam monitoring
  • Application of the Medipix2 technology to space radiation dosimetry and hadron therapy beam monitoring (en)
skos:prefLabel
  • Application of the Medipix2 technology to space radiation dosimetry and hadron therapy beam monitoring
  • Application of the Medipix2 technology to space radiation dosimetry and hadron therapy beam monitoring (en)
skos:notation
  • RIV/68407700:21670/11:00191786!RIV12-MSM-21670___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM6840770040)
http://linked.open...iv/cisloPeriodika
  • 12
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 186866
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21670/11:00191786
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Dosimeter; Pixel detector; Silicon detector; SSDs; Medipix; TimePix; Charge drift (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [C77E1F3CE56B]
http://linked.open...i/riv/nazevZdroje
  • Radiation Measurements
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 46
http://linked.open...iv/tvurceVysledku
  • Empl, A.
  • Jakůbek, Jan
  • Kitamura, H.
  • Leroy, C.
  • Pospíšil, Stanislav
  • Pinsky, L.
  • Stoffle, N.
  • Uchihori, Y.
  • Yasuda, N.
http://linked.open...ain/vavai/riv/wos
  • 000300459400065
http://linked.open...n/vavai/riv/zamer
issn
  • 1350-4487
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.radmeas.2011.08.026
http://localhost/t...ganizacniJednotka
  • 21670
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 25 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software