About: Quality of X-ray Transmission Radiography Based on Single Photon Counting Pixel Device     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • This work devotes to the optimization of digital X ray transmission radiography for the observation of time dependent processes using a single X-ray photon counting pixel device. The maximization of frame rate of acquired roentgenograms is crucial for this purpose. The influence of the X ray tube voltage on exposure time, which is necessary for sufficient quality of roentgenograms, was investigated. Roentgenograms are distorted due to non uniform pixel detection efficiency across the X ray detector. Such distortion can be successfully eliminated by the proposed “Direct thickness calibration method” regardless of X ray beam hardening, which is due to the variation of inspected body absorption.
  • This work devotes to the optimization of digital X ray transmission radiography for the observation of time dependent processes using a single X-ray photon counting pixel device. The maximization of frame rate of acquired roentgenograms is crucial for this purpose. The influence of the X ray tube voltage on exposure time, which is necessary for sufficient quality of roentgenograms, was investigated. Roentgenograms are distorted due to non uniform pixel detection efficiency across the X ray detector. Such distortion can be successfully eliminated by the proposed “Direct thickness calibration method” regardless of X ray beam hardening, which is due to the variation of inspected body absorption. (en)
  • Tato práce je věnována optimalizaci sledování časově závislých procesů metodou rentgenovské radiografie pomocí pixelových detektorů jednotlivých fotonů. Maximalizace četnosti snímků je zásadním problémem této oblasti. Byl studován vliv pracovního bodu rentgenky (napětí) na nutné exposiční časy. Rentgenogramy jsou poškozovány díky nestejné citlivosti jednotlivých pixelů snímače. Toto poškození stejně jako vliv efktu tvrdnutí svazku lze úspěšně odstranit metodou přímé kalibrace tloušťky která je (cs)
Title
  • Quality of X-ray Transmission Radiography Based on Single Photon Counting Pixel Device
  • Kvalita rentgenovské radiografie založené na pixelovém detektoru jednotlivých fotonů (cs)
  • Quality of X-ray Transmission Radiography Based on Single Photon Counting Pixel Device (en)
skos:prefLabel
  • Quality of X-ray Transmission Radiography Based on Single Photon Counting Pixel Device
  • Kvalita rentgenovské radiografie založené na pixelovém detektoru jednotlivých fotonů (cs)
  • Quality of X-ray Transmission Radiography Based on Single Photon Counting Pixel Device (en)
skos:notation
  • RIV/68407700:21670/05:15118446!RIV06-GA0-21670___
http://linked.open.../vavai/riv/strany
  • 113 ; 117
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(1P04LA211), P(GA106/04/0567), Z(AV0Z20710524)
http://linked.open...iv/cisloPeriodika
  • 1-2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 539804
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21670/05:15118446
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Beam Hardenning; Pixel Detectors; Radiografie; X-ray tube (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [74DF7C327512]
http://linked.open...i/riv/nazevZdroje
  • Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • A546
http://linked.open...iv/tvurceVysledku
  • Jakůbek, Jan
  • Pospíšil, Stanislav
  • Vavřík, Daniel
  • Uher, Josef
http://linked.open...n/vavai/riv/zamer
issn
  • 0168-9002
number of pages
http://localhost/t...ganizacniJednotka
  • 21670
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 47 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software