About: Local Skin Exposure of Hands of Workers at Selected Pet Nuclear Medicine Departments in the Czech Republic: Recommended Correction Factors Based on Specific Measurements     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The paper summarizes the local skin exposure of hands of workers at two PET centres in the Czech Republic. Based on three cycles of measurements using thermoluminescent dosimeters, the maximum local skin exposure of hands of workers engaged in dispensing or administering the 18F-labeled radiopharmaceutical has been determined. In addition, the annual hand exposure has been estimated and the relevant correction factors to be used at these centres have been recommended. As to the persons dispensing radiopharmaceuticals, it was estimated that 50% of them can reach the equivalent dose corresponding to the reference level of 150 mSv/y. In the case of the workers administering radiopharmaceutical, it was estimated that 43 % of cases can reach investigation level
  • The paper summarizes the local skin exposure of hands of workers at two PET centres in the Czech Republic. Based on three cycles of measurements using thermoluminescent dosimeters, the maximum local skin exposure of hands of workers engaged in dispensing or administering the 18F-labeled radiopharmaceutical has been determined. In addition, the annual hand exposure has been estimated and the relevant correction factors to be used at these centres have been recommended. As to the persons dispensing radiopharmaceuticals, it was estimated that 50% of them can reach the equivalent dose corresponding to the reference level of 150 mSv/y. In the case of the workers administering radiopharmaceutical, it was estimated that 43 % of cases can reach investigation level (en)
Title
  • Local Skin Exposure of Hands of Workers at Selected Pet Nuclear Medicine Departments in the Czech Republic: Recommended Correction Factors Based on Specific Measurements
  • Local Skin Exposure of Hands of Workers at Selected Pet Nuclear Medicine Departments in the Czech Republic: Recommended Correction Factors Based on Specific Measurements (en)
skos:prefLabel
  • Local Skin Exposure of Hands of Workers at Selected Pet Nuclear Medicine Departments in the Czech Republic: Recommended Correction Factors Based on Specific Measurements
  • Local Skin Exposure of Hands of Workers at Selected Pet Nuclear Medicine Departments in the Czech Republic: Recommended Correction Factors Based on Specific Measurements (en)
skos:notation
  • RIV/68407700:21460/14:00223138!RIV15-MSM-21460___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 26465
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21460/14:00223138
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Nuclear Medicine; 18F; Hp(0.07); Skin Exposure of Hands; Correction Factor (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [BFC4A39A76FA]
http://linked.open...v/mistoKonaniAkce
  • Hradec Králové
http://linked.open...i/riv/mistoVydani
  • Hradec Králové
http://linked.open...i/riv/nazevZdroje
  • 5. mezinárodní Masarykova konference pro doktorandy a mladé vědecké pracovníky
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Hudzietzová, Jana
  • Fülöp, M.
  • Sabol, J.
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • MAGNANIMITAS
https://schema.org/isbn
  • 978-80-87952-07-8
http://localhost/t...ganizacniJednotka
  • 21460
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 78 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software