About: Direct Electrical Stimulation Using a Battery-Operated Device for Induction and Modulation     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Direct electrical stimulation of the colon offers a promising approach for the induction of propulsive colonic contractions by using an implantable device. The objective of this study was to assess the feasibility to induce colonic contractions using a commercially available battery-operated stimulator (maximum pulse width of 1 ms and maximum amplitude of 10 V). Three pairs of pacing electrodes were inserted into the cecal seromuscular layer of anesthetized pigs. During a first set of in vivo experiments conducted on six animals, a pacing protocol leading to cecum contractions was determined: stimulation bursts with 1 ms pulse width, 10 V amplitude (7-15 mA), 120 Hz frequency, and 30-s burst duration, repeated every 2-5 min. In a second testing phase, an evaluation of the pacing protocol was performed in four animals (120 stimulation bursts in total).
  • Direct electrical stimulation of the colon offers a promising approach for the induction of propulsive colonic contractions by using an implantable device. The objective of this study was to assess the feasibility to induce colonic contractions using a commercially available battery-operated stimulator (maximum pulse width of 1 ms and maximum amplitude of 10 V). Three pairs of pacing electrodes were inserted into the cecal seromuscular layer of anesthetized pigs. During a first set of in vivo experiments conducted on six animals, a pacing protocol leading to cecum contractions was determined: stimulation bursts with 1 ms pulse width, 10 V amplitude (7-15 mA), 120 Hz frequency, and 30-s burst duration, repeated every 2-5 min. In a second testing phase, an evaluation of the pacing protocol was performed in four animals (120 stimulation bursts in total). (en)
Title
  • Direct Electrical Stimulation Using a Battery-Operated Device for Induction and Modulation
  • Direct Electrical Stimulation Using a Battery-Operated Device for Induction and Modulation (en)
skos:prefLabel
  • Direct Electrical Stimulation Using a Battery-Operated Device for Induction and Modulation
  • Direct Electrical Stimulation Using a Battery-Operated Device for Induction and Modulation (en)
skos:notation
  • RIV/68407700:21460/10:00168941!RIV11-MSM-21460___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM6840770012)
http://linked.open...iv/cisloPeriodika
  • 7
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 254538
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21460/10:00168941
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Colon; Electrical stimulation; Implantable device (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [A008BDA972FD]
http://linked.open...i/riv/nazevZdroje
  • Annals of Biomedical Engineering
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 38
http://linked.open...iv/tvurceVysledku
  • Kučera, Pavel
  • Aellen, S.
  • Bertschi, M.
  • D´Ambrogio, A.
  • Givel, J.-C.
  • Peloponissios, N.
  • Schlageter, V.
  • Vesin, J.-M.
  • Virag, N.
  • Wiesel, P. H.
http://linked.open...ain/vavai/riv/wos
  • 000278519400013
http://linked.open...n/vavai/riv/zamer
issn
  • 0090-6964
number of pages
http://localhost/t...ganizacniJednotka
  • 21460
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software