  • A confocal laser scanning microscope (CLSM) enables us to capture images from a biological specimen in different depths and obtain a series of precisely registered fluorescent images. But images captured from deep layers of the specimen may be darker than images from the topmost layers due to light loss distortions. This effect causes difficulties in subsequent analysis of biological objects. We propose a solution using two approaches: either an online method working already during image acquisition, or an offline method assisting as a post-processing step. In the online method the gain value of a photomultiplier tube of a CLSM is controlled according to the difference of mean image intensities between the reference and currently acquired image. The offline method consists of two stages. In the first stage a standard histogram improving brightness and contrast is created from all images in the series. In the second stage image histograms are warped according to this standard histogram.
  • A confocal laser scanning microscope (CLSM) enables us to capture images from a biological specimen in different depths and obtain a series of precisely registered fluorescent images. But images captured from deep layers of the specimen may be darker than images from the topmost layers due to light loss distortions. This effect causes difficulties in subsequent analysis of biological objects. We propose a solution using two approaches: either an online method working already during image acquisition, or an offline method assisting as a post-processing step. In the online method the gain value of a photomultiplier tube of a CLSM is controlled according to the difference of mean image intensities between the reference and currently acquired image. The offline method consists of two stages. In the first stage a standard histogram improving brightness and contrast is created from all images in the series. In the second stage image histograms are warped according to this standard histogram. (en)
  • Konfokální laserový mikroskop umožňuje získat 3D obrazy biologického vzorku. Snímání je však zatíženo útlumem jasu a kontrastu obrazů s hloubkou zaostření. Článek popisuje metody kompenzace tohoto útlumu jednak během samotného snímaní a jednak úpravou obrazů po nasnímání. (cs)
Title
  • Methods for Compensation of the Light Attenuation with Depth of Images Captured by a Confocal Microscope
  • Methods for Compensation of the Light Attenuation with Depth of Images Captured by a Confocal Microscope (en)
  • Metody kompenzace útlumu jasu obrazů získaných konfokálním mikroskopem s hloubkou (cs)
skos:prefLabel
  • Methods for Compensation of the Light Attenuation with Depth of Images Captured by a Confocal Microscope
  • Methods for Compensation of the Light Attenuation with Depth of Images Captured by a Confocal Microscope (en)
  • Metody kompenzace útlumu jasu obrazů získaných konfokálním mikroskopem s hloubkou (cs)
skos:notation
  • RIV/68407700:21460/06:12120277!RIV07-MSM-21460___
http://linked.open.../vavai/riv/strany
  • 624;635
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA304/05/0153), P(IAA100110502), P(IAA500200510), P(IAA600110507), P(KJB6011309), P(LC06063), Z(AV0Z50110509), Z(MSM6840770012)
http://linked.open...iv/cisloPeriodika
  • 8
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 485108
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21460/06:12120277
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • confocal microscopy; hardware adjustment; histogram warping; image enhancement; light attenuation (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [99FD652CBB73]
http://linked.open...i/riv/nazevZdroje
  • Microscopy Research and Technique
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 69
http://linked.open...iv/tvurceVysledku
  • Čapek, Martin
  • Janáček, J.
  • Kubínová, L.
http://linked.open...n/vavai/riv/zamer
issn
  • 1059-910X
number of pages
http://localhost/t...ganizacniJednotka
  • 21460
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software