About: Uncertainties in linear energy transfer spectra measured with track-etched detectors in space     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Polyallyldiglycol carbonate-based track-etched detectors can measure linear energy transfer (LET) spectra of charged particles. Accuracy of the spectra is affected by many factors whose effects are difficult to quantify. Typically, only uncertainty arising from the randomness of particle detection is reported in scientific literature. The aim of this paper is to classify the sources of uncertainties of an LET spectrum measurement and provide a simple model for the calculation of the combined uncertainty. The model was used for a spectrum measured with the track-etched detector (Harzlas TD-1) on board of the International Space Station from May-October 2009. For some spectrum bins the largest contribution to the combined uncertainty came from the uncertainty arising from the randomness of particle detection. For other bins it came from the uncertainty of the calibration curve. Contribution from the cross talk between bins was small for most of the bins as the width of the bins was relatively large compared to the intrinsic resolution of the track-etched detector. The analysis showed that sources of uncertainties other than the randomness of particle detection should not, in general, be neglected. (C) 2013 Elsevier B.V. All rights reserved.
  • Polyallyldiglycol carbonate-based track-etched detectors can measure linear energy transfer (LET) spectra of charged particles. Accuracy of the spectra is affected by many factors whose effects are difficult to quantify. Typically, only uncertainty arising from the randomness of particle detection is reported in scientific literature. The aim of this paper is to classify the sources of uncertainties of an LET spectrum measurement and provide a simple model for the calculation of the combined uncertainty. The model was used for a spectrum measured with the track-etched detector (Harzlas TD-1) on board of the International Space Station from May-October 2009. For some spectrum bins the largest contribution to the combined uncertainty came from the uncertainty arising from the randomness of particle detection. For other bins it came from the uncertainty of the calibration curve. Contribution from the cross talk between bins was small for most of the bins as the width of the bins was relatively large compared to the intrinsic resolution of the track-etched detector. The analysis showed that sources of uncertainties other than the randomness of particle detection should not, in general, be neglected. (C) 2013 Elsevier B.V. All rights reserved. (en)
Title
  • Uncertainties in linear energy transfer spectra measured with track-etched detectors in space
  • Uncertainties in linear energy transfer spectra measured with track-etched detectors in space (en)
skos:prefLabel
  • Uncertainties in linear energy transfer spectra measured with track-etched detectors in space
  • Uncertainties in linear energy transfer spectra measured with track-etched detectors in space (en)
skos:notation
  • RIV/68407700:21340/13:00228835!RIV15-MSM-21340___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GA205/09/0171), P(GD202/09/H086), P(IAA100480902), P(KJB100480901), Z(AV0Z10480505)
http://linked.open...iv/cisloPeriodika
  • 0
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 112550
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21340/13:00228835
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • CR-39; Linear energy transfer; Uncertainty model; Space dosimetry (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [D0C830B7DE7C]
http://linked.open...i/riv/nazevZdroje
  • Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 713
http://linked.open...iv/tvurceVysledku
  • Kolísková, Zlata
  • Ambrožová, I.
  • Brabcova, K. P.
  • Malusek, A.
http://linked.open...ain/vavai/riv/wos
  • 000319239300002
http://linked.open...n/vavai/riv/zamer
issn
  • 0168-9002
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.nima.2013.03.012
http://localhost/t...ganizacniJednotka
  • 21340
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 36 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software