About: Accuracy and Benefits of 3D Bone Surface Modelling: A Comparison of Two Methods of Surface Data Acquisition Reconstructed by Laser Scanning and Computed Tomography Outputs     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The aim of this study is to compare two different methods of frontal bone surface model acquisition. Three dimensional models acquired by laser scanning were compared with models of the same bones acquired by virtual replicas reconstructed from a sequence of computed tomography (CT) images. The influence of volumetric CT data processing (namely thresholding), which immediately preceded the generation of the three-dimensional surface model, was also considered and explored in detail in one sample. Despite identifying certain areas where both models showed deviations across all samples, their conformity can be generally classified as satisfactory, and the differences can be regarded as minimal. The average deviation of registered surface models was 0.27 mm for 90% of the data, and its value was therefore very close to the resolution of the laser scanner used.
  • The aim of this study is to compare two different methods of frontal bone surface model acquisition. Three dimensional models acquired by laser scanning were compared with models of the same bones acquired by virtual replicas reconstructed from a sequence of computed tomography (CT) images. The influence of volumetric CT data processing (namely thresholding), which immediately preceded the generation of the three-dimensional surface model, was also considered and explored in detail in one sample. Despite identifying certain areas where both models showed deviations across all samples, their conformity can be generally classified as satisfactory, and the differences can be regarded as minimal. The average deviation of registered surface models was 0.27 mm for 90% of the data, and its value was therefore very close to the resolution of the laser scanner used. (en)
Title
  • Accuracy and Benefits of 3D Bone Surface Modelling: A Comparison of Two Methods of Surface Data Acquisition Reconstructed by Laser Scanning and Computed Tomography Outputs
  • Accuracy and Benefits of 3D Bone Surface Modelling: A Comparison of Two Methods of Surface Data Acquisition Reconstructed by Laser Scanning and Computed Tomography Outputs (en)
skos:prefLabel
  • Accuracy and Benefits of 3D Bone Surface Modelling: A Comparison of Two Methods of Surface Data Acquisition Reconstructed by Laser Scanning and Computed Tomography Outputs
  • Accuracy and Benefits of 3D Bone Surface Modelling: A Comparison of Two Methods of Surface Data Acquisition Reconstructed by Laser Scanning and Computed Tomography Outputs (en)
skos:notation
  • RIV/68407700:21340/12:00202903!RIV13-MSM-21340___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, S, Z(MSM0021620843), Z(MSM6840770022)
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 120868
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21340/12:00202903
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • CT SCANS; SEGMENTATION; ORTHODONTICS; VALIDATION; SKULL (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • HR - Chorvatská republika
http://linked.open...ontrolniKodProRIV
  • [E4AD22929003]
http://linked.open...i/riv/nazevZdroje
  • COLLEGIUM ANTROPOLOGICUM
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 36
http://linked.open...iv/tvurceVysledku
  • Velemínská, J.
  • Prokop, Josef
  • Jančárek, Alexandr
  • Brzobohata, H.
  • Horak, M.
http://linked.open...ain/vavai/riv/wos
  • 000310664100013
http://linked.open...n/vavai/riv/zamer
issn
  • 0350-6134
number of pages
http://localhost/t...ganizacniJednotka
  • 21340
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software