About: Effective Dose to Papient During Cardiac Interventional Procedures (PRAGUE WORKPLACES)     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The aim of the study was to assess effective dose to a patient during cardiac procedures, such as coronary angiography and percutaneous transiluminal angioplasty. Measurements were performed on 185 patients in four catheterization laboratories in three hospitals in Prague using the dose area product (DAP) meter. Calculations on surface and effective dose were performed with Monte-Carlo based program PCXMC. The mean DAP value per procedure determined in all workplaces ranged between 25.0 and 54.5 Gy cm2 for CA and 43.0 -104.5 Gy cm2 for PTCA. In three cases, the surface dose exceeded the 2 Gy level for occurrence of transient erythema. The mean effective dose per procedure in all workplaces was determined to be in the range of 2.7 - 8.8 mSv for CA and 5.7 - 15.3 mSv for CA+PTCA combined. The results are comparable with those published by other authors.
  • The aim of the study was to assess effective dose to a patient during cardiac procedures, such as coronary angiography and percutaneous transiluminal angioplasty. Measurements were performed on 185 patients in four catheterization laboratories in three hospitals in Prague using the dose area product (DAP) meter. Calculations on surface and effective dose were performed with Monte-Carlo based program PCXMC. The mean DAP value per procedure determined in all workplaces ranged between 25.0 and 54.5 Gy cm2 for CA and 43.0 -104.5 Gy cm2 for PTCA. In three cases, the surface dose exceeded the 2 Gy level for occurrence of transient erythema. The mean effective dose per procedure in all workplaces was determined to be in the range of 2.7 - 8.8 mSv for CA and 5.7 - 15.3 mSv for CA+PTCA combined. The results are comparable with those published by other authors. (en)
  • Čtyři katetrizační sály tří pražských nemocnic byly monitorovány pomocí měřidla součinu dávky a plochy (DAP). Naměřené hodnoty dále sloužily k výpočtu povrchové a efektivní dávky. Výpočty byly prováděny pomocí programu PCXMC. Střední hodnota DAP na vyšetření na proměřovaných pracovištích se pohybovala v rozmezí 25.0 - 54.5 Gy cm2 pro koronarografii (CA) a 43.0 - 104.5 Gy cm2 pro angioplastiku (PTCA). Podobně pro efektivní dávku byly zjištěny hodnoty 2.7 - 8.8 mSv pro CA a 5.7 - 15.3 mSv pro PTCA. Povrchová dávka přesáhla u tří pacientů 2 Gy, uvažované jako hranice pro možný výskyt radiační dermatitidy. Výsledky jsou srovnatelné s již dříve publikovanými. (cs)
Title
  • Efektivní dávka pacientovi v průběhu kardiologických intervenčních výkonů (cs)
  • Effective Dose to Papient During Cardiac Interventional Procedures (PRAGUE WORKPLACES)
  • Effective Dose to Papient During Cardiac Interventional Procedures (PRAGUE WORKPLACES) (en)
skos:prefLabel
  • Efektivní dávka pacientovi v průběhu kardiologických intervenčních výkonů (cs)
  • Effective Dose to Papient During Cardiac Interventional Procedures (PRAGUE WORKPLACES)
  • Effective Dose to Papient During Cardiac Interventional Procedures (PRAGUE WORKPLACES) (en)
skos:notation
  • RIV/68407700:21340/04:04101437!RIV/2005/MSM/213405/N
http://linked.open.../vavai/riv/strany
  • 271 ; 274
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM 210000019)
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 562119
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21340/04:04101437
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Radiation protection, radiology, effective dose, DAP, interventional procedures (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [95A448E019CC]
http://linked.open...i/riv/nazevZdroje
  • Radiation Protection Dosimetry
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 111
http://linked.open...iv/tvurceVysledku
  • Štísová, Viktorie
http://linked.open...n/vavai/riv/zamer
issn
  • 0144-8420
number of pages
http://localhost/t...ganizacniJednotka
  • 21340
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 81 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software