About: AC/DC Current Transformer with Single Winding     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • DC currents in power grids are created by induction from geomagnetic variations and newly also by transformerless power inverters installed in solar power stations. These currents may cause serious errors of current transformers (CTs) measuring the consumed energy, but also cause overload of distribution transformers which may result in blackout. Installing DC current sensors into the grid would be very expensive. We have shown that the existing CTs in the grid can be used in the fluxgate mode to simultaneously measure DC current. Utilizing this mode, the CT AC error is inevitably increased. We analyze the sources of these errors and show techniques to reduce them. The experiments were made on the off-the-shelf 500 A/5A CT. We show that the uncompensated 5A DC current without compensation increases its AC amplitude error from 0.1% to 1%. We also found that the dominant additional error was caused by the increased burden. With the optimized design of the excitation circuit it is possible to sense a DC current component with 10% accuracy and reduce the additional AC error from previously reported 1.5% to 0.1% when the DC current component is compensated. This technique can be widely used to improve the AC accuracy of the existing CTs.
  • DC currents in power grids are created by induction from geomagnetic variations and newly also by transformerless power inverters installed in solar power stations. These currents may cause serious errors of current transformers (CTs) measuring the consumed energy, but also cause overload of distribution transformers which may result in blackout. Installing DC current sensors into the grid would be very expensive. We have shown that the existing CTs in the grid can be used in the fluxgate mode to simultaneously measure DC current. Utilizing this mode, the CT AC error is inevitably increased. We analyze the sources of these errors and show techniques to reduce them. The experiments were made on the off-the-shelf 500 A/5A CT. We show that the uncompensated 5A DC current without compensation increases its AC amplitude error from 0.1% to 1%. We also found that the dominant additional error was caused by the increased burden. With the optimized design of the excitation circuit it is possible to sense a DC current component with 10% accuracy and reduce the additional AC error from previously reported 1.5% to 0.1% when the DC current component is compensated. This technique can be widely used to improve the AC accuracy of the existing CTs. (en)
Title
  • AC/DC Current Transformer with Single Winding
  • AC/DC Current Transformer with Single Winding (en)
skos:prefLabel
  • AC/DC Current Transformer with Single Winding
  • AC/DC Current Transformer with Single Winding (en)
skos:notation
  • RIV/68407700:21230/13:00207125!RIV14-MSM-21230___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GAP102/12/2177)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 59327
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21230/13:00207125
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • current transformer; single winding (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [D92814D9FF20]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Draxler, Karel
  • Ripka, Pavel
  • Styblíková, R.
http://localhost/t...ganizacniJednotka
  • 21230
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software