  • Magnetoresistors can replace induction sensors in applications like nondestructive testing and metal detection, where high spatial resolution or low frequency response is required. Using an AC excitation field the magnetic response of eddy currents is detected. Although giant magnetoresistive (GMR) sensors have higher measuring range and sensitivity compared to anisotropic magnetoresistors (AMR), they show also higher hysteresis and noise especially at low frequencies. Therefore AMR sensors are chosen to be evaluated in low noise measurements with combined processing of DC and AC excitation field with respect to the arrangement of processing electronics. Circuit with a commercial AMR sensor HMC1001 and AD8429 preamplifier has the noise of 125 pT/rtHz at 1 Hz using the flipping technique. Without the flipping, the noise combined with the 1/f noise of the amplifier results in 246 pT/rtHz at 1 Hz.
  • Magnetoresistors can replace induction sensors in applications like nondestructive testing and metal detection, where high spatial resolution or low frequency response is required. Using an AC excitation field the magnetic response of eddy currents is detected. Although giant magnetoresistive (GMR) sensors have higher measuring range and sensitivity compared to anisotropic magnetoresistors (AMR), they show also higher hysteresis and noise especially at low frequencies. Therefore AMR sensors are chosen to be evaluated in low noise measurements with combined processing of DC and AC excitation field with respect to the arrangement of processing electronics. Circuit with a commercial AMR sensor HMC1001 and AD8429 preamplifier has the noise of 125 pT/rtHz at 1 Hz using the flipping technique. Without the flipping, the noise combined with the 1/f noise of the amplifier results in 246 pT/rtHz at 1 Hz. (en)
Title
  • Low Frequency Noise of Anisotropic Magnetoresistors in AC-excited Magnetometers
  • Low Frequency Noise of Anisotropic Magnetoresistors in AC-excited Magnetometers (en)
skos:prefLabel
  • Low Frequency Noise of Anisotropic Magnetoresistors in AC-excited Magnetometers
  • Low Frequency Noise of Anisotropic Magnetoresistors in AC-excited Magnetometers (en)
skos:notation
  • RIV/68407700:21230/12:00194968!RIV13-MSM-21230___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GD102/09/H082), S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 147492
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21230/12:00194968
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Magnetoresistors; magnetometers (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [9066CF958EE8]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Janošek, Michal
  • Ripka, Pavel
  • Vyhnánek, Jan
http://localhost/t...ganizacniJednotka
  • 21230
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 24 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software