About: Patient monitoring using bioimpedance signal     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The paper presents the development of prototype system for measurement of vital functions using the transthoracic bioimpedance. The measurement of the bioimpedance is a non-invasive method providing the information about the body composition, hearth rate, blood flow, breathing etc. The design and realization of a simple four electrode system have been done. The device is designed as a combination of a signal generator with stabilized current output and a measuring amplifier based on the AD620 amplifier. The output signal includes information about the basic vital signs and could be used as a part of telemonitoring system for the elderly and persons after the organs failure. The device will be used for research and educational purposes in the Smart Home facility at the Czech Technical University in Prague.
  • The paper presents the development of prototype system for measurement of vital functions using the transthoracic bioimpedance. The measurement of the bioimpedance is a non-invasive method providing the information about the body composition, hearth rate, blood flow, breathing etc. The design and realization of a simple four electrode system have been done. The device is designed as a combination of a signal generator with stabilized current output and a measuring amplifier based on the AD620 amplifier. The output signal includes information about the basic vital signs and could be used as a part of telemonitoring system for the elderly and persons after the organs failure. The device will be used for research and educational purposes in the Smart Home facility at the Czech Technical University in Prague. (en)
Title
  • Patient monitoring using bioimpedance signal
  • Patient monitoring using bioimpedance signal (en)
skos:prefLabel
  • Patient monitoring using bioimpedance signal
  • Patient monitoring using bioimpedance signal (en)
skos:notation
  • RIV/68407700:21230/12:00194699!RIV13-MSM-21230___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S, Z(MSM6840770012)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 157951
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21230/12:00194699
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • bioimpedance; vital functions; cardiac output; blood flow (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [2AA38BE1A6A9]
http://linked.open...v/mistoKonaniAkce
  • Vienna
http://linked.open...i/riv/mistoVydani
  • Heidelberg
http://linked.open...i/riv/nazevZdroje
  • Information Technology in Bio- and Medical Informatics
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Havlík, Jan
  • Ložek, Miroslav
  • Fousek, Ondřej
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
issn
  • 0302-9743
number of pages
http://purl.org/ne...btex#hasPublisher
  • Springer-Verlag
https://schema.org/isbn
  • 978-3-642-32394-2
http://localhost/t...ganizacniJednotka
  • 21230
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software