Attributes | Values |
---|
rdf:type
| |
Description
| - On the basis of our personal experience of studying co-temporary scientific articles and the modelling of flow and pressure patterns in systemic vascular beds, we are encouraged to claim, that extremely small patients can experience systemic arterial hypertension generated by pulsatile a left ventricular assist device (LVAD. After implantation of LVAD with the same stroke volume (65ml), all patients have the same average flow during the ejection period, i.e. 65ml for 300ms (13 l/min!). The average flow for the ejection period, the average blood flow during the ejection period through the entire systemic vascular bed is higher in non-physiological terms for extremely small patients and may cause iatrogenic systemic arterial hypertension. In addition we suppose a large %22stroke mismatch%22 (large disproportion between the primary stroke volume and the artificial one) could cause unexpected events like brain bleed
- On the basis of our personal experience of studying co-temporary scientific articles and the modelling of flow and pressure patterns in systemic vascular beds, we are encouraged to claim, that extremely small patients can experience systemic arterial hypertension generated by pulsatile a left ventricular assist device (LVAD. After implantation of LVAD with the same stroke volume (65ml), all patients have the same average flow during the ejection period, i.e. 65ml for 300ms (13 l/min!). The average flow for the ejection period, the average blood flow during the ejection period through the entire systemic vascular bed is higher in non-physiological terms for extremely small patients and may cause iatrogenic systemic arterial hypertension. In addition we suppose a large %22stroke mismatch%22 (large disproportion between the primary stroke volume and the artificial one) could cause unexpected events like brain bleed (en)
|
Title
| - Can We Generate Systemic Arterial Hypertension by Pulsatile LVAD in Our Patients?
- Can We Generate Systemic Arterial Hypertension by Pulsatile LVAD in Our Patients? (en)
|
skos:prefLabel
| - Can We Generate Systemic Arterial Hypertension by Pulsatile LVAD in Our Patients?
- Can We Generate Systemic Arterial Hypertension by Pulsatile LVAD in Our Patients? (en)
|
skos:notation
| - RIV/68407700:21230/11:00186583!RIV13-MSM-21230___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68407700:21230/11:00186583
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - LVAD; arterial hypertension (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Huňka, Petr
- Ježek, Filip
- Macků, David
|
http://linked.open...n/vavai/riv/zamer
| |
http://localhost/t...ganizacniJednotka
| |