About: Phasor Measurement Units in Power System Monitoring     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Large power system disturbances and their consequences represent a challenging problem for the power industry and especially for system operators who are responsible for the network operation, its security and reliability. This fact has reinforced interest in the new generation of monitoring systems with the aim to gain a precise and maximum knowledge about those disturbances and their impact. Most of these severe events with impact on the entire system typically occur in or near the transmission system (TS) and are therefore best monitored at TS level. This puts great demands on the equipments and in general restricts the use of the data since it becomes property of the TSO. Synchronized Phasor Measurement System has emerged as a powerful tool to improve power systems performance and reliability and fault localization possibility. An example of fault event that occurred in TS and was registered by Phasor Measurement Units installed in the distribution system will be shown.
  • Large power system disturbances and their consequences represent a challenging problem for the power industry and especially for system operators who are responsible for the network operation, its security and reliability. This fact has reinforced interest in the new generation of monitoring systems with the aim to gain a precise and maximum knowledge about those disturbances and their impact. Most of these severe events with impact on the entire system typically occur in or near the transmission system (TS) and are therefore best monitored at TS level. This puts great demands on the equipments and in general restricts the use of the data since it becomes property of the TSO. Synchronized Phasor Measurement System has emerged as a powerful tool to improve power systems performance and reliability and fault localization possibility. An example of fault event that occurred in TS and was registered by Phasor Measurement Units installed in the distribution system will be shown. (en)
Title
  • Phasor Measurement Units in Power System Monitoring
  • Phasor Measurement Units in Power System Monitoring (en)
skos:prefLabel
  • Phasor Measurement Units in Power System Monitoring
  • Phasor Measurement Units in Power System Monitoring (en)
skos:notation
  • RIV/68407700:21230/10:00175778!RIV11-MSM-21230___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S, Z(MSM6840770017)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 278745
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21230/10:00175778
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • phasor measurement unit; wide area monitoring; power system security and reliability (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [72795C998B9A]
http://linked.open...v/mistoKonaniAkce
  • Praha
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • Sborník konference ELEN 2010
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Müller, Miroslav
  • Müller, Zdeněk
  • Sýkora, Tomáš
  • Tlustý, Josef
  • Švec, Jan
  • Šrom, Jakub
  • Kasembe, Andrew Gayo
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • České vysoké učení technické v Praze. Fakulta elektrotechnická. Katedra elektroenergetiky
https://schema.org/isbn
  • 978-80-254-8089-2
http://localhost/t...ganizacniJednotka
  • 21230
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software