| - We used electrocardiography (ECG) and photoplethysmography (PPG) to compute pulse arrival time (PAT) between heart and finger. PAT was measured as time difference between the R-peak of ECG and a characteristic point of PPG. We defined different characteristic points of PPG and compared their suitability for blood pressure (BP) estimation. Measurements were made on a group of 13 young males using sphygmomanometric BP measurement as reference. Generally, best results were achieved when using time intervals from R-peak of ECG to the local minimum preceding the rising edge of PPG. However, for some participants, another parameters gave better results.
- We used electrocardiography (ECG) and photoplethysmography (PPG) to compute pulse arrival time (PAT) between heart and finger. PAT was measured as time difference between the R-peak of ECG and a characteristic point of PPG. We defined different characteristic points of PPG and compared their suitability for blood pressure (BP) estimation. Measurements were made on a group of 13 young males using sphygmomanometric BP measurement as reference. Generally, best results were achieved when using time intervals from R-peak of ECG to the local minimum preceding the rising edge of PPG. However, for some participants, another parameters gave better results. (en)
|
Title
| - Usability of ECG and PPG for Continuous Blood Pressure Monitoring
- Usability of ECG and PPG for Continuous Blood Pressure Monitoring (en)
|
skos:prefLabel
| - Usability of ECG and PPG for Continuous Blood Pressure Monitoring
- Usability of ECG and PPG for Continuous Blood Pressure Monitoring (en)
|
skos:notation
| - RIV/68407700:21230/10:00174108!RIV11-GA0-21230___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(GD102/08/H008), S, Z(MSM6840770012)
|
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68407700:21230/10:00174108
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - electrocardiography; photoplethysmography; blood pressure; continuous measurement; pulse arrival time (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - Digital Technologies 2010
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Čmejla, Roman
- Špulák, Daniel
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open.../riv/zahajeniAkce
| |
http://linked.open...n/vavai/riv/zamer
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| - Žilinská univerzita v Žiline
|
https://schema.org/isbn
| |
http://localhost/t...ganizacniJednotka
| |