About: Koaxiální kapacitní etalony 1pF a 10pF     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Four terminal-pair coaxial capacitance standards of nominal value of 1 pF and 10 pF have been realized, with initial accuracy better than 0,005 %. Parasitic inductances of the standards have been calculated and their contribution to frequency dependence of their values has been evaluated. In comparison with previous design of capacitance standards, mechanical dimensions of standards have been significantly reduced, standards have a linear lay-out of BNC connectors. Thanks to that fact, it is possible to connect capacitance standards to commercial-available LCR meters directly without any cable adaptors. Change of capacitance of 1pF, resp. 10 pF in the frequency range 1 kHz up to 1 MHz does not exceed value of 0,015%, resp. 0,02 %. The design of these standards is a partial result of solving the project %22Electrical impedance calibrations%22 of the MSM6840770015 research program. (en)
  • Byly realizovány čtyrpárové koaxiální kapacitní etalony jmenovité hodnoty 1pF a 10 pF s chybou adjustace menší než 0,005 %. Byly vypočteny parazitní indukčnosti etalonů a byl vyhodnocen jejich příspěvek ke kmitočtové závislosti jejich hodnot. Ve srovnání s předchozí konstrukční verzí se významně zmenšila jejich celková velikost, etalony mají lineární uspořádání použitých BNC konektorů. Díky tomu je možné etalony připojit k běžným komerčním RLC mostům přímo bez použití kabelových adaptorů. Změna kapacity etalonu jmenovité hodnoty 1pF, resp. 10pF v pásmu kmitočtu 1 kHz až 1 MHz nepřekročí hodnotu 0,015 %, resp. 0,02% . Konstrukční provedení těchto etalonů je dílčím výsledkem řešení dílčího úkolu %22Etalonáž elektrické impedance%22 výzkumného záměru MSM6840770015.
  • Byly realizovány čtyrpárové koaxiální kapacitní etalony jmenovité hodnoty 1pF a 10 pF s chybou adjustace menší než 0,005 %. Byly vypočteny parazitní indukčnosti etalonů a byl vyhodnocen jejich příspěvek ke kmitočtové závislosti jejich hodnot. Ve srovnání s předchozí konstrukční verzí se významně zmenšila jejich celková velikost, etalony mají lineární uspořádání použitých BNC konektorů. Díky tomu je možné etalony připojit k běžným komerčním RLC mostům přímo bez použití kabelových adaptorů. Změna kapacity etalonu jmenovité hodnoty 1pF, resp. 10pF v pásmu kmitočtu 1 kHz až 1 MHz nepřekročí hodnotu 0,015 %, resp. 0,02% . Konstrukční provedení těchto etalonů je dílčím výsledkem řešení dílčího úkolu %22Etalonáž elektrické impedance%22 výzkumného záměru MSM6840770015. (cs)
Title
  • Koaxiální kapacitní etalony 1pF a 10pF
  • 1pF and 10 pF Coaxial Capacitance Standards (en)
  • Koaxiální kapacitní etalony 1pF a 10pF (cs)
skos:prefLabel
  • Koaxiální kapacitní etalony 1pF a 10pF
  • 1pF and 10 pF Coaxial Capacitance Standards (en)
  • Koaxiální kapacitní etalony 1pF a 10pF (cs)
skos:notation
  • RIV/68407700:21230/10:00171898!RIV11-MSM-21230___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM6840770015)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...onomickeParametry
  • 50 000 Kč/ks
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 266583
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21230/10:00171898
http://linked.open...terniIdentifikace
  • Sada koax.kap. etalonů (2.verze)
http://linked.open...riv/jazykVysledku
http://linked.open...vai/riv/kategorie
http://linked.open.../riv/klicovaSlova
  • capacitance standards, frequency dependence (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [1068BAC2123D]
http://linked.open.../licencniPoplatek
http://linked.open...okalizaceVysledku
  • Katedra měření (lab.T2: C4-S152b)
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...echnickeParametry
  • jmenovité hodnoty: 1 pF, 10 pF; chyba adjustace: < 50ppm; frekveční závislost kapacity: <0,02 %. Vlastníkem výsledku je ČVUT v Praze, IČ 68407700.
http://linked.open...iv/tvurceVysledku
  • Boháček, Jaroslav
  • Kučera, Jan
  • Sedláček, Radek
http://linked.open...avai/riv/vlastnik
http://linked.open...itiJinymSubjektem
http://linked.open...n/vavai/riv/zamer
http://localhost/t...ganizacniJednotka
  • 21230
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software