About: Possibilities of Use Absorption Cooling for Building Air Conditioning System     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The paper analyzes the possibilities of use absorption cooling units instead of conventionally used compressor chiller as a source of chilled water for car showroom building air conditioning system in Prague. Car showroom building was subjected to dynamic energy simulation to determine the internal and external heat gains. The need for cooling of ventilation system was determined based on the hourly calculation based on the climatic data. The evaluation criterion is the economic return of a given source of chilled water. Absorption cooling units were compared in five different embodiments in terms of heat sources (thermal) energy. The results of the analysis clearly does not favor investigated the source of chilled water and it is necessary to take into account all the inputs for the selection of particular chilled water source. (en)
  • Příspěvek analyzuje možnosti uplatnění absorpčního chladicího zařízení na místo konvenčně používané kompresorové chladicí jednotky, jako zdroje chladu pro systém klimatizace budovy autosalonu byla podrobena dynamické energetické simulaci pro zjištění průběhu citelné tepelné zátěže během roku. Potřeba chladu pro větrání byla stanovena na základě hodinového výpočtu vycházející z použitých klimatických dat. Hodnotícím kritériem je ekonomická návratnost systému s daným zdrojem chladu. Absoprční zdroje chladu byly porovnávány v pěti různých provedeních z hlediska zdroje pohonné (tepelné) energie. Výsledky analýzy jednoznačně nezvýhodňují některý ze zkoumaných zdrojů chladu pro zadaný objekt a je nutné při jeho volbě zhodnotit veškeré vstupní parametry.
  • Příspěvek analyzuje možnosti uplatnění absorpčního chladicího zařízení na místo konvenčně používané kompresorové chladicí jednotky, jako zdroje chladu pro systém klimatizace budovy autosalonu byla podrobena dynamické energetické simulaci pro zjištění průběhu citelné tepelné zátěže během roku. Potřeba chladu pro větrání byla stanovena na základě hodinového výpočtu vycházející z použitých klimatických dat. Hodnotícím kritériem je ekonomická návratnost systému s daným zdrojem chladu. Absoprční zdroje chladu byly porovnávány v pěti různých provedeních z hlediska zdroje pohonné (tepelné) energie. Výsledky analýzy jednoznačně nezvýhodňují některý ze zkoumaných zdrojů chladu pro zadaný objekt a je nutné při jeho volbě zhodnotit veškeré vstupní parametry. (cs)
Title
  • Possibilities of Use Absorption Cooling for Building Air Conditioning System (en)
  • Absorpční chlazení jako zdroj chladu pro klimatizaci autosalonu
  • Absorpční chlazení jako zdroj chladu pro klimatizaci autosalonu (cs)
skos:prefLabel
  • Possibilities of Use Absorption Cooling for Building Air Conditioning System (en)
  • Absorpční chlazení jako zdroj chladu pro klimatizaci autosalonu
  • Absorpční chlazení jako zdroj chladu pro klimatizaci autosalonu (cs)
skos:notation
  • RIV/68407700:21220/14:00221803!RIV15-MSM-21220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 1365
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21220/14:00221803
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Heat gain; Absorption cooling; ESP-r (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [83224CEF8FAA]
http://linked.open...v/mistoKonaniAkce
  • Praha
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • Simulace budov a techniky prostředí 2014 - sborník 8. konference IBPSA-CZ
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Zmrhal, Vladimír
  • Begeni, Marek
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • IBPSA-CZ
https://schema.org/isbn
  • 978-80-260-7209-6
http://localhost/t...ganizacniJednotka
  • 21220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 84 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software