About: Research and developlment of CO2 capture and storage technologies in fossil fuel power plants     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The paper deals with calculation procedure that has been performed in order to evaluate suitability of a post-combustion CCS technology application in a recent power plant in the Czech Republic. In the paper is described the ammonia CO2 absorption method and its advantages and disadvantages. The technology scheme with key components of the ammonia CCS has been analyzed and more detailed data is provided for each basic component, especially energy consumption for cooling and compression. In the paper is evaluated the proposed impact on the recent technology of a 250 MWe pulverized lignite coal fired power plant. The calculations are based on available operation input data of the power plant and main parameters (e.g. net power output, efficiency or consumptions) are compared for the recent situation and after CCS installation. The main impact of the ammonia CCS technology application is decrease of electric efficiency by 11 percent points, decrease of net electricity production by 62 MWe and increase of wastewater amount and need of consumables. The decrease of efficiency and net electricity production is particularly caused by high-energy demands of compression of CO2 and cooling of the CO2 - ammonia absorber. Also important is increase of cooling water consumption for the absorbing stage.
  • The paper deals with calculation procedure that has been performed in order to evaluate suitability of a post-combustion CCS technology application in a recent power plant in the Czech Republic. In the paper is described the ammonia CO2 absorption method and its advantages and disadvantages. The technology scheme with key components of the ammonia CCS has been analyzed and more detailed data is provided for each basic component, especially energy consumption for cooling and compression. In the paper is evaluated the proposed impact on the recent technology of a 250 MWe pulverized lignite coal fired power plant. The calculations are based on available operation input data of the power plant and main parameters (e.g. net power output, efficiency or consumptions) are compared for the recent situation and after CCS installation. The main impact of the ammonia CCS technology application is decrease of electric efficiency by 11 percent points, decrease of net electricity production by 62 MWe and increase of wastewater amount and need of consumables. The decrease of efficiency and net electricity production is particularly caused by high-energy demands of compression of CO2 and cooling of the CO2 - ammonia absorber. Also important is increase of cooling water consumption for the absorbing stage. (en)
Title
  • Research and developlment of CO2 capture and storage technologies in fossil fuel power plants
  • Research and developlment of CO2 capture and storage technologies in fossil fuel power plants (en)
skos:prefLabel
  • Research and developlment of CO2 capture and storage technologies in fossil fuel power plants
  • Research and developlment of CO2 capture and storage technologies in fossil fuel power plants (en)
skos:notation
  • RIV/68407700:21220/12:00201729!RIV13-MSM-21220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(FR-TI1/379), Z(MSM6840770035)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 165105
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21220/12:00201729
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • post-combustion; CCS; ammonia (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [E374B3105487]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Hrdlička, Jan
  • Pilař, Lukáš
  • Slouka, P.
http://linked.open...n/vavai/riv/zamer
http://localhost/t...ganizacniJednotka
  • 21220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software