About: DIC as an Evaluation Tool for in-vitro Coronary Stent Implantation     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The Intracoronary stenting (PCI) has become standard revascularization interventional technique worldwide. Significant effort has been made in experimental simulations to optimize stent implantation procedure. However a number of issues remain unresolved. Besides general questions such as the extent of injury, minimizing the compliance mismatch between a stent and an artery, optimal stent diameter, and a strut design, also curved shapes of arteries, and material properties of lesions have to be of concern. Our study should show whether the digital image correlation (DIC) is suitable method to evaluate displacements of the surface of the artery during experimental ex vivo stent expansion. The balloon-expandable CoCr coronary stent Kaname (Terumo Corporation, Tokyo, Japan) was deployed into the sample of the left anterior descending coronary artery of a 40 years old male donor with multiple atherosclerotic lesions. Displacement measurement was conducted with commercial 3D DIC system Dantec Q-450 (Dantec Dynamics, Ulm, Germany). DIC post-processing showed significant total displacements in the range 1.45-2.45mm with position of peak values corresponding to estimated end-points of deployed stent. Hence 3D DIC seems to be helpful tool within experimental of ex vivo stent implantation.
  • The Intracoronary stenting (PCI) has become standard revascularization interventional technique worldwide. Significant effort has been made in experimental simulations to optimize stent implantation procedure. However a number of issues remain unresolved. Besides general questions such as the extent of injury, minimizing the compliance mismatch between a stent and an artery, optimal stent diameter, and a strut design, also curved shapes of arteries, and material properties of lesions have to be of concern. Our study should show whether the digital image correlation (DIC) is suitable method to evaluate displacements of the surface of the artery during experimental ex vivo stent expansion. The balloon-expandable CoCr coronary stent Kaname (Terumo Corporation, Tokyo, Japan) was deployed into the sample of the left anterior descending coronary artery of a 40 years old male donor with multiple atherosclerotic lesions. Displacement measurement was conducted with commercial 3D DIC system Dantec Q-450 (Dantec Dynamics, Ulm, Germany). DIC post-processing showed significant total displacements in the range 1.45-2.45mm with position of peak values corresponding to estimated end-points of deployed stent. Hence 3D DIC seems to be helpful tool within experimental of ex vivo stent implantation. (en)
Title
  • DIC as an Evaluation Tool for in-vitro Coronary Stent Implantation
  • DIC as an Evaluation Tool for in-vitro Coronary Stent Implantation (en)
skos:prefLabel
  • DIC as an Evaluation Tool for in-vitro Coronary Stent Implantation
  • DIC as an Evaluation Tool for in-vitro Coronary Stent Implantation (en)
skos:notation
  • RIV/68407700:21220/12:00192645!RIV13-MSM-21220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GAP108/10/1296), S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 131045
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21220/12:00192645
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • corronary stent; artery; DIC (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [5A22F18B74E4]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Chlup, Hynek
  • Horný, Lukáš
  • Veselý, Jan
  • Žitný, Rudolf
http://localhost/t...ganizacniJednotka
  • 21220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software