| - The DAQ system was prepared for the commissioning of the TOTEM Roman Pot detectors. The system developed on the PVSS II, ver 3.6, SCADA platform provides remote multi-user access to the online data, to assure safe operation of the RP that is in the commissioning process. The systems high level architecture is SERVER-CLIENT oriented, when SERVER is placed locally in the area of the commissioning and CLIENTs can be, thanks to the TCP/IP based communication, geographically located anywhere within reach of the Internet connection. Necessary data are obtained from different types of temperature, pressure and flow-meter sensing elements. The system manages in summary communication with three ELMB units, up to 192 sensor readings, data-base with all historical values and real-time remote access to all those data to any number of observers.
- The DAQ system was prepared for the commissioning of the TOTEM Roman Pot detectors. The system developed on the PVSS II, ver 3.6, SCADA platform provides remote multi-user access to the online data, to assure safe operation of the RP that is in the commissioning process. The systems high level architecture is SERVER-CLIENT oriented, when SERVER is placed locally in the area of the commissioning and CLIENTs can be, thanks to the TCP/IP based communication, geographically located anywhere within reach of the Internet connection. Necessary data are obtained from different types of temperature, pressure and flow-meter sensing elements. The system manages in summary communication with three ELMB units, up to 192 sensor readings, data-base with all historical values and real-time remote access to all those data to any number of observers. (en)
|
Title
| - DAQ system for the RP commissioning
- DAQ system for the RP commissioning (en)
|
skos:prefLabel
| - DAQ system for the RP commissioning
- DAQ system for the RP commissioning (en)
|
skos:notation
| - RIV/68407700:21220/10:00173297!RIV11-MSM-21220___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...onomickeParametry
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68407700:21220/10:00173297
|
http://linked.open...terniIdentifikace
| |
http://linked.open...riv/jazykVysledku
| |
http://linked.open...vai/riv/kategorie
| |
http://linked.open.../riv/klicovaSlova
| - DAQ; ELMB; SCADA; evaporative cooling; TOTEM (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open.../licencniPoplatek
| |
http://linked.open...okalizaceVysledku
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...echnickeParametry
| - 192 kanálový automatizovaný systém sběru dat včetně senzorů (Pt, NTC, tlak, průtok). Vlastníkem výsledku je ČVUT v Praze, IČ 68407700.
|