About: Zatěžovací mechanismus pro kinematickou analýzu páteřních segmentů in-vitro     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Device allows loading of spinal functional unit of 2 to 3 vertebrae based on in-vivo measurements and its results using modern imaging devices. Motion trajectory of the most distant vertebrae is described in the form of instantaneous axis of rotation. Device is intended for measuring in combination with motion capture devices such as VICON, QUALISYS etc. Rigid construction support defines the global coordinate system. With minimum of 3 markers for each vertebral body, the spatial coordinate system can be easily defined and any changes in kinematic parameters of the movement in the same loading scheme can be calculated. This system is used for analysis of the artificial intervertebral disc prosthesis and the influence of various positions with respect to the optimal position. The result has been created within the scope of thematic task TU A2.2 MSM6840770012 - Transdisciplinary research in the field of biomedical engineering II. The specimen is used by CTU in Prague. (en)
  • Zařízení umožňuje namáhat páteřní segment 2-3 obratlů dle výsledků získaných z měření in-vivo pomocí moderních zobrazovacích metod. Trajektorie pohybu krajních obratlů je popsána pomocí okamžitých středů otáčení. Mechanismus je určen pro měření v kombinaci se zařízeními pro kinematickou analýzu jako je VICON, QUALISYS, atd. Pevný support definuje globální souřadný systém. S minimem 3 markerů na každé tělo obratle je možné stanovit lokální systémy a sledovat změny v pohybových parametrech při stejném zatížení před a po implementaci meziobratlových náhrad v různých pozicích vzhledem k pozici %22optimální%22. Vzniklo v rámci řešení tématického úkolu TÚ A2.2 MSM6840770012 - Transdisciplinární výzkum v oblasti biomedicínského inženýrství II. Uživatelem výsledku je ČVUT v Praze.
  • Zařízení umožňuje namáhat páteřní segment 2-3 obratlů dle výsledků získaných z měření in-vivo pomocí moderních zobrazovacích metod. Trajektorie pohybu krajních obratlů je popsána pomocí okamžitých středů otáčení. Mechanismus je určen pro měření v kombinaci se zařízeními pro kinematickou analýzu jako je VICON, QUALISYS, atd. Pevný support definuje globální souřadný systém. S minimem 3 markerů na každé tělo obratle je možné stanovit lokální systémy a sledovat změny v pohybových parametrech při stejném zatížení před a po implementaci meziobratlových náhrad v různých pozicích vzhledem k pozici %22optimální%22. Vzniklo v rámci řešení tématického úkolu TÚ A2.2 MSM6840770012 - Transdisciplinární výzkum v oblasti biomedicínského inženýrství II. Uživatelem výsledku je ČVUT v Praze. (cs)
Title
  • Zatěžovací mechanismus pro kinematickou analýzu páteřních segmentů in-vitro
  • Zatěžovací mechanismus pro kinematickou analýzu páteřních segmentů in-vitro (cs)
  • The loading mechanism for the kinematic analysis of spinal segments in vitro (en)
skos:prefLabel
  • Zatěžovací mechanismus pro kinematickou analýzu páteřních segmentů in-vitro
  • Zatěžovací mechanismus pro kinematickou analýzu páteřních segmentů in-vitro (cs)
  • The loading mechanism for the kinematic analysis of spinal segments in vitro (en)
skos:notation
  • RIV/68407700:21220/10:00170696!RIV11-MSM-21220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(FT-TA3/131), S, Z(MSM6840770012)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...onomickeParametry
  • Cena 25 000 Kč
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 299708
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21220/10:00170696
http://linked.open...terniIdentifikace
  • 12105-P06-2010.10
http://linked.open...riv/jazykVysledku
http://linked.open...vai/riv/kategorie
http://linked.open.../riv/klicovaSlova
  • Spinal biomechanics; Spine; Kinematic analysis; Instantaneous axis of rotation; Intervertebral disc (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [BE69982BCC96]
http://linked.open.../licencniPoplatek
http://linked.open...okalizaceVysledku
  • Katedra anatomie a biomechaniky FTVS UK, Jose Martino 31, Praha 6, laboratoř Extremních zátěží (BEZ)
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...echnickeParametry
  • rozměry základového roštu 1,3 x 0,9m. Vlastníkem výsledku je ČVUT v Praze, IČ 68407700.
http://linked.open...iv/tvurceVysledku
  • Kuželka, Jiří
  • Kronek, Jakub
  • Otáhal, Martin
  • Holub, Ondřej
  • Otáhal, S.
http://linked.open...avai/riv/vlastnik
http://linked.open...itiJinymSubjektem
http://linked.open...n/vavai/riv/zamer
http://localhost/t...ganizacniJednotka
  • 21220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software