  • In the present study the in vitro tensile properties of the porcine extensor digitorum profundus tendons were obtained. For a measurement the testing system MTS Mini Bionix 858.2 was used. Data were obtained from displacement of jaws and with an extensometer. Data from displacement of jaws are influenced of slip specimens from jaws. The problem of the tendon sidle out of the jaws was solved. For the better fixation of tendon in jaws during tensile tests the new profile of jaws component were developed. Next innovation in tendon fixing comes with the cooling the tendon ends by liquid nitrogen before clamping. With the measuring setup with frozen ends and jagged rounded profile of jaws can be obtained satisfactory strain data without using of an extensometer.
  • In the present study the in vitro tensile properties of the porcine extensor digitorum profundus tendons were obtained. For a measurement the testing system MTS Mini Bionix 858.2 was used. Data were obtained from displacement of jaws and with an extensometer. Data from displacement of jaws are influenced of slip specimens from jaws. The problem of the tendon sidle out of the jaws was solved. For the better fixation of tendon in jaws during tensile tests the new profile of jaws component were developed. Next innovation in tendon fixing comes with the cooling the tendon ends by liquid nitrogen before clamping. With the measuring setup with frozen ends and jagged rounded profile of jaws can be obtained satisfactory strain data without using of an extensometer. (en)
  • V prezentovaném příspěvku jsou experimentálně získávány pevnostní parametry vepřových šlach extensor digitorum profundus. Byl použit testovací systém MTS Mini Bionix 858.2. Deformační data byly získávány jednak z velikostí rozevření čelistí a jednak z extenzometru upevněného na měřící šlaše. Ukázalo se, že data získaná z posunutí čelistí jsou ovlivněna vyklouzáváním materiálu šlachy z čelistí. Tento problém vyklouzávání šlachy byl řešen návrhem nových čelisťových vložek pro zvětšení třecí plochy. Pro další snížení koeficientu tření bylo použito chlazení upevněných konců šlachy tekutým dusíkem. Pomocí takovéhoto uchycení se zmrzlými konci šlachy v čelistech se zaoblenými zuby byly získány uspokojivé výsledky měření deformace z posunutí čelistí, které byly téměř totožné s výsledky získanými pomocí extenzometru. Tímto alternativním způsobem uchycení šlachy je možné získat její deformaci i bez použití mnohdy nákladného extenzometru. (cs)
Title
  • The New Solution of Clamping Problem in Tendon Strain Estimation Without Using of an Extensometer
  • Nové řešení uchycení šlachy pro stanovení její deformace bez použití extenzometru (cs)
  • The New Solution of Clamping Problem in Tendon Strain Estimation Without Using of an Extensometer (en)
skos:prefLabel
  • The New Solution of Clamping Problem in Tendon Strain Estimation Without Using of an Extensometer
  • Nové řešení uchycení šlachy pro stanovení její deformace bez použití extenzometru (cs)
  • The New Solution of Clamping Problem in Tendon Strain Estimation Without Using of an Extensometer (en)
skos:notation
  • RIV/68407700:21220/08:02147678!RIV09-MSM-21220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GP106/06/P304), Z(MSM6840770012)
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 382657
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21220/08:02147678
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • high strength biological material; material testing; tendon (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • SK - Slovenská republika
http://linked.open...ontrolniKodProRIV
  • [B52CC2548E50]
http://linked.open...i/riv/nazevZdroje
  • Acta Mechanica Slovaca
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 12
http://linked.open...iv/tvurceVysledku
  • Vilímek, Miloslav
  • Konvičková, Svatava
http://linked.open...n/vavai/riv/zamer
issn
  • 1335-2393
number of pages
http://localhost/t...ganizacniJednotka
  • 21220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software