| - Normally when the jet velocities are measured in the occupied zone, the total performance/function of the system is not possible to see. In the location of the wall-floor corner is possible draft risk. In the lab conditions, the measurement were conducted to analyze the width of the jet profiles around the ceiling, walls and corners and further the possible draft risk when the jet turns in the occupied zone.
- Normally when the jet velocities are measured in the occupied zone, the total performance/function of the system is not possible to see. In the location of the wall-floor corner is possible draft risk. In the lab conditions, the measurement were conducted to analyze the width of the jet profiles around the ceiling, walls and corners and further the possible draft risk when the jet turns in the occupied zone. (en)
- Většina běžných měření rychlostí a teplot pro posouzení tepelného komfortu člověka se provádí v zoně pobytu. To však častokrát neumožňuje vidět celkový obraz proudění v místnosti. V případě větrání chladicími trámci se jedná zejména o proudění okolo stropu, zdí a podlahy. Okolo stěny může dojít k zrychlení proudu a následnému pocitu průvanu po vstupu proudu do zóny pobytu při podlaze. V laboratorních podmínkách bylo provedeno měření proudění okolo stropu, zdi a podlahy v místnosti větrané chladicími trámci a jeho analýza a vyhodnocen dopad na tepelný komfort. (cs)
|
Title
| - Local Air Distribution Effects in Rooms with Chilled Beams.
- Local Air Distribution Effects in Rooms with Chilled Beams. (en)
- Lokální proudění v místnostech větraných chladicími trámci. (cs)
|
skos:prefLabel
| - Local Air Distribution Effects in Rooms with Chilled Beams.
- Local Air Distribution Effects in Rooms with Chilled Beams. (en)
- Lokální proudění v místnostech větraných chladicími trámci. (cs)
|
skos:notation
| - RIV/68407700:21220/07:02133433!RIV08-MSM-21220___
|
http://linked.open.../vavai/riv/strany
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68407700:21220/07:02133433
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - chilled beams, draught risk, thermal comfort, flow pattern, interaction, air jet (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - Roomvent 2007 - 10th International Conference on Air Distribution in Rooms
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Zbořil, Viktor
- Kosonen, R.
- Melikov, A.
- Yordanova, B.