About: Signal Processing of Bioimpedance Equipment     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Measurement of the electrical impedance of tissue is used as a non-invasive method especially in diag-nostics of the cardiovascular system. Impe-dance changes in the tissue are influenced by blood flow in this tissue. The changes provide hemodynamic information. When scanning bioimpedance signals on the periphery of the body it is necessity to construct the bio-impedance measuring equipment in such a way that maximum sensitivity of the arrangement is achieved by maximum suppression of interfering signals and noise. An adaptive digital filter, optimised on the basis of an analysis of the bioimpedance signal, achieves a marked decrease in the interference level and noise, and increases its diagnostic value. It extends the application range of the bioimpedance method for tracing the hemodynamics not only of the heart and major arteries but also of tissues and organs.
  • Measurement of the electrical impedance of tissue is used as a non-invasive method especially in diag-nostics of the cardiovascular system. Impe-dance changes in the tissue are influenced by blood flow in this tissue. The changes provide hemodynamic information. When scanning bioimpedance signals on the periphery of the body it is necessity to construct the bio-impedance measuring equipment in such a way that maximum sensitivity of the arrangement is achieved by maximum suppression of interfering signals and noise. An adaptive digital filter, optimised on the basis of an analysis of the bioimpedance signal, achieves a marked decrease in the interference level and noise, and increases its diagnostic value. It extends the application range of the bioimpedance method for tracing the hemodynamics not only of the heart and major arteries but also of tissues and organs. (en)
Title
  • Signal Processing of Bioimpedance Equipment
  • Signal Processing of Bioimpedance Equipment (en)
skos:prefLabel
  • Signal Processing of Bioimpedance Equipment
  • Signal Processing of Bioimpedance Equipment (en)
skos:notation
  • RIV/68407700:21220/03:02093252!RIV/2004/MSM/212204/N
http://linked.open.../vavai/riv/strany
  • 328 ; 335
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM 210000012)
http://linked.open...iv/cisloPeriodika
  • 1-3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 626952
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21220/03:02093252
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • adaptive digital filter,signal processing,hemodynamics,bioimpedance (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [311156FCCDE3]
http://linked.open...i/riv/nazevZdroje
  • Sensors and Actuators B: Chemical
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 95
http://linked.open...iv/tvurceVysledku
  • Papežová, Stanislava
http://linked.open...n/vavai/riv/zamer
issn
  • 0925-4005
number of pages
http://localhost/t...ganizacniJednotka
  • 21220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software