Attributes | Values |
---|
rdf:type
| |
Description
| - The pilot scale verification has been launched on a gabion structure situated at the boundary of the house lot in Slivenecká street no. 1149/23, 152 00 Prague 5 – Hlubočepy in the immediate proximity of the railway line no. 122 (Prague-Smíchov – Hostivice – Rudná u Prahy). In the framework of the performed harmonization of the panel for maximum acoustic attenuation with the technical legislation, technical documentation was worked out for the product approval by the respective transport infrastructure administrations. Gabion structures approx. 75 m long and 2.5 m high were installed along the northern boundary of the house lot. In the first, 35 m long section, which begins close to a level crossing, a multifunctional gabion structure was installed, which is followed by a section of standard gabion structure approx. 40 m long. The aim of the pilot scale verification is to confirm that utilization of multifunctional gabions results in reduction of negative effects of transport noise emissions. (en)
- Poloprovozní ověřování bylo zahájeno na stavbě gabionu situované na hranici pozemku rodinného domu Slivenecká 1149/23, 152 00 Praha 5 – Hlubočepy v bezprostředním sousedství s železniční tratí č. 122 (Praha-Smíchov – Hostivice – Rudná u Prahy). V rámci provedené harmonizace PHD s technickou legislativou byly zhotoveny technické podklady pro schválení výrobku resortními správci dopravní infrastruktury. Na těchto činnostech se podíleli všichni řešitelé. Gabionové konstrukce délky cca 75 a výšky cca 2,5 m nad úrovní terénu jsou instalovány podél severní hranice parcely rodinného domu. V prvním úseku v délce cca 35 m, začínajícím u železničního přejezdu je instalována multifunkční gabionová konstrukce na kterou navazuje v délce cca 40 m standardní gabionová konstrukce. Cílem poloprovozního ověření je potvrdit snížení negativního dopadu hlukových emisí z dopravy.
- Poloprovozní ověřování bylo zahájeno na stavbě gabionu situované na hranici pozemku rodinného domu Slivenecká 1149/23, 152 00 Praha 5 – Hlubočepy v bezprostředním sousedství s železniční tratí č. 122 (Praha-Smíchov – Hostivice – Rudná u Prahy). V rámci provedené harmonizace PHD s technickou legislativou byly zhotoveny technické podklady pro schválení výrobku resortními správci dopravní infrastruktury. Na těchto činnostech se podíleli všichni řešitelé. Gabionové konstrukce délky cca 75 a výšky cca 2,5 m nad úrovní terénu jsou instalovány podél severní hranice parcely rodinného domu. V prvním úseku v délce cca 35 m, začínajícím u železničního přejezdu je instalována multifunkční gabionová konstrukce na kterou navazuje v délce cca 40 m standardní gabionová konstrukce. Cílem poloprovozního ověření je potvrdit snížení negativního dopadu hlukových emisí z dopravy. (cs)
|
Title
| - Pilot scale verification of a multifungtional gabion structure (en)
- Poloprovozní ověřování multifunkční gabionové konstrukce
- Poloprovozní ověřování multifunkční gabionové konstrukce (cs)
|
skos:prefLabel
| - Pilot scale verification of a multifungtional gabion structure (en)
- Poloprovozní ověřování multifunkční gabionové konstrukce
- Poloprovozní ověřování multifunkční gabionové konstrukce (cs)
|
skos:notation
| - RIV/68407700:21110/14:00226572!RIV15-TA0-21110___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...onomickeParametry
| - Porovnání ceny s protihlukovou stěnou stejné výšky vykazuje 500,- Kč na běžném metru snížení ceny, ale dosažený akustický útlum Multifunkčního gabionu je vyšší, odpovídá kategorii A4.
|
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68407700:21110/14:00226572
|
http://linked.open...terniIdentifikace
| |
http://linked.open...riv/jazykVysledku
| |
http://linked.open...vai/riv/kategorie
| |
http://linked.open.../riv/klicovaSlova
| - gabion structure; the panel for maximum acoustic attenuation; level crossing; multifunctional gabion structure; transport noise emissions (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open.../licencniPoplatek
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...echnickeParametry
| - Prohlášení SŽDC s.o. ze 21.11.2014, Ing. Jiří Kozák, ředitel OTH, Dlážděná 1003/7, Praha 1, Protokol o posouzení vlastností č.1020-CPR-040 047431 ze dne 17.12.2014, Stavební technické osvědčení č.090-029474 ze dne 7.5.2013
|
http://linked.open...iv/tvurceVysledku
| - Krejčiříková, Hana
- Hartmann, M.
- Suchánek, A.
- Šafner, K.
|
http://linked.open...avai/riv/vlastnik
| |
http://linked.open...itiJinymSubjektem
| |
http://localhost/t...ganizacniJednotka
| |