  • The utilisation of steel fibre reinforced concrete (SFRC) instead of traditional reinforced concrete (RC) for some structures can bring many advantages. All advantages are given by properties of SFRC, partly by strength properties, mainly by strain characteristics. An appropriate concrete structure for utilisation of SFRC can be tunnel lining generated from precast concrete segments. The loading of precast concrete segments, namely during installation of segments, leads often to mechanical damage of joints. The utilisation of SFRC for tunnel segments can reduce damage of joints, which is one of many advantages of the SFRC utilisation for tunnel segments. The main goal is to show approach to replacement of used material (i.e. approach from the design of concrete composition to results of experimental testing of key segment generated from SFRC without traditional rebars). Properties of SFRC were verified on standard samples. Uniaxial strength was veri-fied on cubes (150 mm), flexural strength was verified on beams (700 x 150 x 150 mm). Two dosages of steel fibres (50 kg/m3 and 70 kg/m3) together with two types of steel fibres (Dramix and Tri Treg) were verified by laboratory testing to achieve material stability during transport, tunnel lining installa-tion, and during its lifetime, mainly with regards to given thickness of segments 250 mm (construction of Prague metro line A extension).
  • The utilisation of steel fibre reinforced concrete (SFRC) instead of traditional reinforced concrete (RC) for some structures can bring many advantages. All advantages are given by properties of SFRC, partly by strength properties, mainly by strain characteristics. An appropriate concrete structure for utilisation of SFRC can be tunnel lining generated from precast concrete segments. The loading of precast concrete segments, namely during installation of segments, leads often to mechanical damage of joints. The utilisation of SFRC for tunnel segments can reduce damage of joints, which is one of many advantages of the SFRC utilisation for tunnel segments. The main goal is to show approach to replacement of used material (i.e. approach from the design of concrete composition to results of experimental testing of key segment generated from SFRC without traditional rebars). Properties of SFRC were verified on standard samples. Uniaxial strength was veri-fied on cubes (150 mm), flexural strength was verified on beams (700 x 150 x 150 mm). Two dosages of steel fibres (50 kg/m3 and 70 kg/m3) together with two types of steel fibres (Dramix and Tri Treg) were verified by laboratory testing to achieve material stability during transport, tunnel lining installa-tion, and during its lifetime, mainly with regards to given thickness of segments 250 mm (construction of Prague metro line A extension). (en)
Title
  • Laboratory testing of SFRC samples proposed for tunnel lining segments
  • Laboratory testing of SFRC samples proposed for tunnel lining segments (en)
skos:prefLabel
  • Laboratory testing of SFRC samples proposed for tunnel lining segments
  • Laboratory testing of SFRC samples proposed for tunnel lining segments (en)
skos:notation
  • RIV/68407700:21110/13:00207144!RIV14-GA0-21110___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GAP104/10/2023)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 84187
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21110/13:00207144
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • tunnel; segmental lining; steel fibre reinforced concrete; SFRC; experimental testing (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [59377240C665]
http://linked.open...v/mistoKonaniAkce
  • Praha
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • Podzemní stavby 2013 - Proceedings
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Krátký, Jiří
  • Vodička, Jan
  • Hilar, Matouš
  • Ráček, Václav
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Czech Tunnelling Association ITA-AITES
https://schema.org/isbn
  • 978-80-260-3868-9
http://localhost/t...ganizacniJednotka
  • 21110
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software