About: Prestressing Losses in Sungular Struture Areas and the Cross Section Warping Effect – Full Scale Test     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Reliable design of prestressed concrete elements and structures have to be based on the accurate determination of prestressing force (including losses and their time development) to satisfy stress as well as deformation limits. Commonly used obsolete computational routines and methods neglect or incorrectly describe real effects and the results obtained by analysis based on these methods are thus necessarily misleading – great differences from results obtained by measurements on real structures have been found. After 50 years of precast concrete members used for Vienna metro is possible to compare real outputs from full scale test with theory for prestressing force determination include the new approaches for real 3D behaviour.
  • Reliable design of prestressed concrete elements and structures have to be based on the accurate determination of prestressing force (including losses and their time development) to satisfy stress as well as deformation limits. Commonly used obsolete computational routines and methods neglect or incorrectly describe real effects and the results obtained by analysis based on these methods are thus necessarily misleading – great differences from results obtained by measurements on real structures have been found. After 50 years of precast concrete members used for Vienna metro is possible to compare real outputs from full scale test with theory for prestressing force determination include the new approaches for real 3D behaviour. (en)
Title
  • Prestressing Losses in Sungular Struture Areas and the Cross Section Warping Effect – Full Scale Test
  • Prestressing Losses in Sungular Struture Areas and the Cross Section Warping Effect – Full Scale Test (en)
skos:prefLabel
  • Prestressing Losses in Sungular Struture Areas and the Cross Section Warping Effect – Full Scale Test
  • Prestressing Losses in Sungular Struture Areas and the Cross Section Warping Effect – Full Scale Test (en)
skos:notation
  • RIV/68407700:21110/13:00206294!RIV14-MSM-21110___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 99088
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21110/13:00206294
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • cross section warping; prestressing losses (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [F1F63E7E4D42]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Loško, Jan
http://localhost/t...ganizacniJednotka
  • 21110
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software