About: Hygric, thermal and durability properties of autoclaved aerated concrete     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The hygric and thermal properties of autoclaved aerated concrete (AAC) given in the manufacturers’ lists include mostly just the thermal conductivity in dry state and generic data for the specific heat capacity and water vapor diffusion resistance factor. Durability characteristics are not listed at all. This greatly limits any service life assessment studies of AAC-based building envelope systems. In this paper, complete sets of hygric and thermal properties of three commercially produced AAC with different bulk density and compressive strength are measured, together with the basic physical characteristics and durability properties. Experimental results show that the thermal conductivity can be as much as six times higher in capillary water saturation state than in dry conditions. Thermal conductivity is also found to increase up to 50% when temperature is increased from 2 C to 40 C. The dependence of moisture diffusivity on moisture content is remarkable; the differences as high as one order of magnitude are observed if its values obtained for low and high moisture contents are compared. The freeze/thaw resistance of capillary saturated samples is found satisfactory up to 25 cycles and increases with compressive strength. For the moisture content lower than 10% by volume AAC in the range of compressive strength of 1.8–4 MPa can successfully resist to 50 cycles.
  • The hygric and thermal properties of autoclaved aerated concrete (AAC) given in the manufacturers’ lists include mostly just the thermal conductivity in dry state and generic data for the specific heat capacity and water vapor diffusion resistance factor. Durability characteristics are not listed at all. This greatly limits any service life assessment studies of AAC-based building envelope systems. In this paper, complete sets of hygric and thermal properties of three commercially produced AAC with different bulk density and compressive strength are measured, together with the basic physical characteristics and durability properties. Experimental results show that the thermal conductivity can be as much as six times higher in capillary water saturation state than in dry conditions. Thermal conductivity is also found to increase up to 50% when temperature is increased from 2 C to 40 C. The dependence of moisture diffusivity on moisture content is remarkable; the differences as high as one order of magnitude are observed if its values obtained for low and high moisture contents are compared. The freeze/thaw resistance of capillary saturated samples is found satisfactory up to 25 cycles and increases with compressive strength. For the moisture content lower than 10% by volume AAC in the range of compressive strength of 1.8–4 MPa can successfully resist to 50 cycles. (en)
Title
  • Hygric, thermal and durability properties of autoclaved aerated concrete
  • Hygric, thermal and durability properties of autoclaved aerated concrete (en)
skos:prefLabel
  • Hygric, thermal and durability properties of autoclaved aerated concrete
  • Hygric, thermal and durability properties of autoclaved aerated concrete (en)
skos:notation
  • RIV/68407700:21110/13:00200639!RIV14-GA0-21110___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GBP105/12/G059)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 78520
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21110/13:00200639
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Autoclaved aerated concrete; Hygric properties; Thermal properties; Durability properties (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [953B24FF82B7]
http://linked.open...i/riv/nazevZdroje
  • Construction and Building Materials
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 41
http://linked.open...iv/tvurceVysledku
  • Jerman, Miloš
  • Keppert, Martin
  • Výborný, Jaroslav
  • Černý, Robert
http://linked.open...ain/vavai/riv/wos
  • 000317528900040
issn
  • 0950-0618
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.conbuildmat.2012.12.036
http://localhost/t...ganizacniJednotka
  • 21110
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software