  • It is frequently a task to calibrate the radiogram intensity in reference to the object thickness/density value. This knowledge is important when the radiographic densitometry, thickness measurements or precise computed tomography are required. Often aluminum is used as calibrating material and processed radiogram of the real object is evaluated as aluminum equivalent. This approach is qualitatively convenient for transmission radiograms; however, certain secondary artifacts remain in CT reconstructions. Fortunately the calibration function can be shaped using only one or two known thickness values of the object investigated. The shaped calibration function obtained produces the right signal to thickness relationship and CT quality is improved when it is applied.
  • It is frequently a task to calibrate the radiogram intensity in reference to the object thickness/density value. This knowledge is important when the radiographic densitometry, thickness measurements or precise computed tomography are required. Often aluminum is used as calibrating material and processed radiogram of the real object is evaluated as aluminum equivalent. This approach is qualitatively convenient for transmission radiograms; however, certain secondary artifacts remain in CT reconstructions. Fortunately the calibration function can be shaped using only one or two known thickness values of the object investigated. The shaped calibration function obtained produces the right signal to thickness relationship and CT quality is improved when it is applied. (en)
Title
  • CT Artefact Reduction by Signal to Thickness Calibration Function Shaping
  • CT Artefact Reduction by Signal to Thickness Calibration Function Shaping (en)
skos:prefLabel
  • CT Artefact Reduction by Signal to Thickness Calibration Function Shaping
  • CT Artefact Reduction by Signal to Thickness Calibration Function Shaping (en)
skos:notation
  • RIV/68378297:_____/11:00365109!RIV12-AV0-68378297
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA103/09/2101), P(LA08015), Z(AV0Z20710524)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 192413
http://linked.open...ai/riv/idVysledku
  • RIV/68378297:_____/11:00365109
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • flat field correction; digital radiography; signal to thickness function; beam hardnening correction (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [A040BE444B02]
http://linked.open...i/riv/nazevZdroje
  • Nuclear Instruments & Methods in Physics Research Section A
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 633
http://linked.open...iv/tvurceVysledku
  • Vavřík, Daniel
http://linked.open...ain/vavai/riv/wos
  • 000292782400054
http://linked.open...n/vavai/riv/zamer
issn
  • 0168-9002
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.nima.2010.06.160
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software