| - Assessment of material properties of isolated human trabeculae is highly influenced by precision of the sample preparation. Article deals with describing of the pre-testing procedure for the uniaxial testing, nanoindentation and finite element modeling of single trabeculae. The first part is focused on the specimen resection, delipidation and fixation in a novel high precision experimental device which enables to measure the strains optically using a high-resolution CCD camera. The second part deals with the development of the volumetric model of the trabecula required for numerical analysis. The last part is dedicated to optimization of polishing procedure used sample surface preparation for nanoindentation. Effect of the grain size, load and duration time of the grinding on final surface roughness was analyzed.
- Assessment of material properties of isolated human trabeculae is highly influenced by precision of the sample preparation. Article deals with describing of the pre-testing procedure for the uniaxial testing, nanoindentation and finite element modeling of single trabeculae. The first part is focused on the specimen resection, delipidation and fixation in a novel high precision experimental device which enables to measure the strains optically using a high-resolution CCD camera. The second part deals with the development of the volumetric model of the trabecula required for numerical analysis. The last part is dedicated to optimization of polishing procedure used sample surface preparation for nanoindentation. Effect of the grain size, load and duration time of the grinding on final surface roughness was analyzed. (en)
|
Title
| - Evaluation of sample preparation procedures for micro-mechanical testing of trabecular bone
- Evaluation of sample preparation procedures for micro-mechanical testing of trabecular bone (en)
|
skos:prefLabel
| - Evaluation of sample preparation procedures for micro-mechanical testing of trabecular bone
- Evaluation of sample preparation procedures for micro-mechanical testing of trabecular bone (en)
|
skos:notation
| - RIV/68378297:_____/11:00359883!RIV12-AV0-68378297
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(GAP105/10/2305), S, Z(AV0Z20710524), Z(MSM6840770043)
|
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68378297:_____/11:00359883
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - micro-mechanical testing; sample preparation; trabecular bone (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - 10th Youth Symposium on Experimental Solid Mechanics
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Doktor, T.
- Jiroušek, Ondřej
- Kytýř, D.
- Valach, J.
- Zlámal, Petr
- Kostelecká, M.
|