  • This work is devoted to the application of tomographic techniques for %22X-ray dynamic defectoscopy%22 (XRDD). The XRDD method enables the on-line observation of material density variations with micrometric accuracy thanks to the good spatial resolution and sensitivity of the single X-ray photon counting pixel Medipix-1detector. The test specimen is illuminated by X-rays during the loading process. Measured changes in transmission represent effective alternations in the specimen thickness, which are understood as weakening of the material due to volume voids resulting from loading stress. Volume voids in the specimen are projected onto a single two dimensional image. Variation in void density along the beam can be determined by tomographic methods. This paper studies the applicability of tomographic techniques for XRDD and presents results of preliminary experiments
  • This work is devoted to the application of tomographic techniques for %22X-ray dynamic defectoscopy%22 (XRDD). The XRDD method enables the on-line observation of material density variations with micrometric accuracy thanks to the good spatial resolution and sensitivity of the single X-ray photon counting pixel Medipix-1detector. The test specimen is illuminated by X-rays during the loading process. Measured changes in transmission represent effective alternations in the specimen thickness, which are understood as weakening of the material due to volume voids resulting from loading stress. Volume voids in the specimen are projected onto a single two dimensional image. Variation in void density along the beam can be determined by tomographic methods. This paper studies the applicability of tomographic techniques for XRDD and presents results of preliminary experiments (en)
  • Tato práce je věnovaná použití tomografické techniky pro X-ray dynamickou defektoskopii (XRDD). Díky dobrému prostorovému rozlišení a citlivosti detektoru Medipix-1 jednotlivých X-fotonů umožňuje metoda XRDD online pozorování změn hustoty materiálu a to s mikrometrickou přesností. Testovaný vzorek je během zatěžovacího procesu prosvěcován X-zářením. Měřené rozdíly procházejícího záření představují efektivní změny tloušťky vzorku, které jsou brány jako oslabení materiálu objemovým zastoupením dutin, jež jsou důsledkem napjatosti vzorku. Objemový podíl dutin ve vzorku je projektován do dvojdimenzionálního obrázku. Změny v hustotě dutin podél svazku mohou být určeny tomograficky. V této práci je zkoumána použitelnost tomografických technik pro XRDD a jsou zde prezentovány první výsledky (cs)
Title
  • Tomography for XRDD
  • Tomography for XRDD (en)
  • Využití tomografie pro XRDD (cs)
skos:prefLabel
  • Tomography for XRDD
  • Tomography for XRDD (en)
  • Využití tomografie pro XRDD (cs)
skos:notation
  • RIV/68378297:_____/04:00106144!RIV/2005/AV0/A14005/N
http://linked.open.../vavai/riv/strany
  • 307;313
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA106/04/0567), Z(AV0Z2071913)
http://linked.open...iv/cisloPeriodika
  • 2004
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 590448
http://linked.open...ai/riv/idVysledku
  • RIV/68378297:_____/04:00106144
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Radiography;Tomography;Silicon pixel detector (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [DA02DFC700AB]
http://linked.open...i/riv/nazevZdroje
  • Nuclear Instruments and Methods in Physics Research Section A
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 531
http://linked.open...iv/tvurceVysledku
  • Jakůbek, J.
  • Vavřík, Daniel
  • Holý, T.
  • Pospíšil, S.
http://linked.open...n/vavai/riv/zamer
issn
  • 0168-9002
number of pages
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software