Attributes | Values |
---|
rdf:type
| |
Description
| - Cr-doped (GdX, Y1X)3Al5O12 (X = 0, 0.25, 0.50) crystals prepared by the micro-pulling down method were investigated to develop a infra-red scintillator for implantable patient dosimeter in radiation therapy. In order to evaluate their optical and scintillation performance, the following properties were measured: (i) transmittance between ultra-violet and near-infra red region, (ii) photoluminescence spectra under Xe-lamp excitation, and (iii) X-ray excited radio-luminescence spectra.
- Cr-doped (GdX, Y1X)3Al5O12 (X = 0, 0.25, 0.50) crystals prepared by the micro-pulling down method were investigated to develop a infra-red scintillator for implantable patient dosimeter in radiation therapy. In order to evaluate their optical and scintillation performance, the following properties were measured: (i) transmittance between ultra-violet and near-infra red region, (ii) photoluminescence spectra under Xe-lamp excitation, and (iii) X-ray excited radio-luminescence spectra. (en)
|
Title
| - Luminescent properties of Cr-doped (Gdx, Y1-x)3Al5O12 infra-red scintillator crystals
- Luminescent properties of Cr-doped (Gdx, Y1-x)3Al5O12 infra-red scintillator crystals (en)
|
skos:prefLabel
| - Luminescent properties of Cr-doped (Gdx, Y1-x)3Al5O12 infra-red scintillator crystals
- Luminescent properties of Cr-doped (Gdx, Y1-x)3Al5O12 infra-red scintillator crystals (en)
|
skos:notation
| - RIV/68378271:_____/14:00440060!RIV15-AV0-68378271
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68378271:_____/14:00440060
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - infra-red scintillator; patient dosimetry; Cr-doped oxide garnet; bulk crystal (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Kamada, K.
- Pejchal, Jan
- Suzuki, A.
- Yokota, Y.
- Yoshikawa, A.
- Yamaji, A.
- Kurosawa, S.
- Shoji, Y.
|
http://linked.open...ain/vavai/riv/wos
| |
issn
| |
number of pages
| |
http://bibframe.org/vocab/doi
| - 10.1016/j.optmat.2014.04.002
|