About: Intra-observer error of mouse long bone cross section digitization     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Digitization of periosteal and endosteal contours of bone cross section is one of several methods used for calculating long bone cross-sectional geometry (CSG). In this study, invasively obtained bone histological samples were used to calculate intra-observer measurement error for CSG parameters. Intra-observer error was measured based upon repeated measurements of cross-sectional areas (total area [TA], cortical area [CA]) and moments of area (I-max, I-min, I-max/I-min, J) in B6CBA mice (n = 17). Cross sections were cut at 50 % of the biomechanical length of the left tibia and the samples were further processed for CSG and histological analysis. Intra-observer error was measured to estimate the accuracy of the digitization method. Accuracy of the tested digitization method was expressed by mean difference (MD), mean absolute difference (MAD), and limits of agreement (LA). The results confirm our assumption that intra-observer error decreases with the number of repeated measurement events. Thus, the error can be minimized by acquiring experience in the section digitizing. Our results also show that TA, CA and polar moment of area (J) are more susceptible to intra-observer error than are I-max, I-min and I-max/I-min.
  • Digitization of periosteal and endosteal contours of bone cross section is one of several methods used for calculating long bone cross-sectional geometry (CSG). In this study, invasively obtained bone histological samples were used to calculate intra-observer measurement error for CSG parameters. Intra-observer error was measured based upon repeated measurements of cross-sectional areas (total area [TA], cortical area [CA]) and moments of area (I-max, I-min, I-max/I-min, J) in B6CBA mice (n = 17). Cross sections were cut at 50 % of the biomechanical length of the left tibia and the samples were further processed for CSG and histological analysis. Intra-observer error was measured to estimate the accuracy of the digitization method. Accuracy of the tested digitization method was expressed by mean difference (MD), mean absolute difference (MAD), and limits of agreement (LA). The results confirm our assumption that intra-observer error decreases with the number of repeated measurement events. Thus, the error can be minimized by acquiring experience in the section digitizing. Our results also show that TA, CA and polar moment of area (J) are more susceptible to intra-observer error than are I-max, I-min and I-max/I-min. (en)
Title
  • Intra-observer error of mouse long bone cross section digitization
  • Intra-observer error of mouse long bone cross section digitization (en)
skos:prefLabel
  • Intra-observer error of mouse long bone cross section digitization
  • Intra-observer error of mouse long bone cross section digitization (en)
skos:notation
  • RIV/68081766:_____/12:00390442!RIV13-GA0-68081766
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GA206/09/0589), S
http://linked.open...iv/cisloPeriodika
  • 3-4
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 142758
http://linked.open...ai/riv/idVysledku
  • RIV/68081766:_____/12:00390442
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • accuracy; cortical bone; CSG; digitization; tibia (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [643AAB5F0242]
http://linked.open...i/riv/nazevZdroje
  • Folia zoologica
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 61
http://linked.open...iv/tvurceVysledku
  • Sládek, Vladimír
  • Jindrová, A.
  • Tůma, J.
http://linked.open...ain/vavai/riv/wos
  • 000313606500015
issn
  • 0139-7893
number of pages
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software