About: Performance of SEM Scintillation Detector Evaluated by Modulation Transfer Function and Detective Quantum Efficiency Function     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • In the paper, the SEM detector is evaluated by the modulation transfer function (MTF) which expresses the detector’s influence on the SEM image contrast. This is a novel approach, since the MTF was used previously to describe only the area imaging detectors, or whole imaging systems. The measurement technique and calculation of the MTF for the SEM detector are presented. In addition, the measurement and calculation of the detective quantum efficiency (DQE) as a function of the spatial frequency for the SEM detector are described. In this technique, the time modulated ebeam is used in order to create well-defined input signal for the detector. The MTF and DQE measurements are demonstrated on the Everhart–Thornley scintillation detector. This detector was alternated using the YAG:Ce, YAP:Ce, and CRY18 single-crystal scintillators. The presented MTF and DQE characteristics show good imaging properties of the detectors with the YAP:Ce or CRY18 scintillator, especially for a specific type of the ebeamscan. The results demonstrate the great benefit of the description of SEMdetectors using theMTF and DQE. In addition, point-by-point and continual-sweep e-beam scans in SEM were discussed and their influence on the image quality was revealed using the MTF.
  • In the paper, the SEM detector is evaluated by the modulation transfer function (MTF) which expresses the detector’s influence on the SEM image contrast. This is a novel approach, since the MTF was used previously to describe only the area imaging detectors, or whole imaging systems. The measurement technique and calculation of the MTF for the SEM detector are presented. In addition, the measurement and calculation of the detective quantum efficiency (DQE) as a function of the spatial frequency for the SEM detector are described. In this technique, the time modulated ebeam is used in order to create well-defined input signal for the detector. The MTF and DQE measurements are demonstrated on the Everhart–Thornley scintillation detector. This detector was alternated using the YAG:Ce, YAP:Ce, and CRY18 single-crystal scintillators. The presented MTF and DQE characteristics show good imaging properties of the detectors with the YAP:Ce or CRY18 scintillator, especially for a specific type of the ebeamscan. The results demonstrate the great benefit of the description of SEMdetectors using theMTF and DQE. In addition, point-by-point and continual-sweep e-beam scans in SEM were discussed and their influence on the image quality was revealed using the MTF. (en)
Title
  • Performance of SEM Scintillation Detector Evaluated by Modulation Transfer Function and Detective Quantum Efficiency Function
  • Performance of SEM Scintillation Detector Evaluated by Modulation Transfer Function and Detective Quantum Efficiency Function (en)
skos:prefLabel
  • Performance of SEM Scintillation Detector Evaluated by Modulation Transfer Function and Detective Quantum Efficiency Function
  • Performance of SEM Scintillation Detector Evaluated by Modulation Transfer Function and Detective Quantum Efficiency Function (en)
skos:notation
  • RIV/68081731:_____/14:00430357!RIV15-TA0-68081731
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(EE.2.3.20.0103), P(GAP102/10/1410), P(TE01020118)
http://linked.open...iv/cisloPeriodika
  • 4
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 36161
http://linked.open...ai/riv/idVysledku
  • RIV/68081731:_____/14:00430357
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • MTF; DQE; image detection; scintillator; e-beam scanning (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [9D8693AFADC6]
http://linked.open...i/riv/nazevZdroje
  • Scanning
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 36
http://linked.open...iv/tvurceVysledku
  • Bok, Jan
  • Schauer, Petr
http://linked.open...ain/vavai/riv/wos
  • 000340537200002
issn
  • 0161-0457
number of pages
http://bibframe.org/vocab/doi
  • 10.1002/sca.21130
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software