About: Single-Channel Blind Estimation of Arterial Input Function and Tissue Impulse Response in DCE-MRI     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Multipass dynamic MRI and pharmacokinetic modeling are used to estimate perfusion parameters of leaky capillaries. Curve fitting and nonblind deconvolution are the established methods to derive the perfusion estimates from the observed arterial input function (AIF) and tissue tracer concentration function. These nonblind methods are sensitive to errors in the AIF, measured in some nearby artery or estimated by multichannel blind deconvolution. Here, a single-channel blind deconvolution algorithm is presented, which only uses a single tissue tracer concentration function to estimate the corresponding AIF and tissue impulse response function. That way, many errors affecting these functions are reduced. The validity of the algorithm is supported by simulations and tests on real data from mouse. The corresponding nonblind and multichannel methods are also presented.
  • Multipass dynamic MRI and pharmacokinetic modeling are used to estimate perfusion parameters of leaky capillaries. Curve fitting and nonblind deconvolution are the established methods to derive the perfusion estimates from the observed arterial input function (AIF) and tissue tracer concentration function. These nonblind methods are sensitive to errors in the AIF, measured in some nearby artery or estimated by multichannel blind deconvolution. Here, a single-channel blind deconvolution algorithm is presented, which only uses a single tissue tracer concentration function to estimate the corresponding AIF and tissue impulse response function. That way, many errors affecting these functions are reduced. The validity of the algorithm is supported by simulations and tests on real data from mouse. The corresponding nonblind and multichannel methods are also presented. (en)
Title
  • Single-Channel Blind Estimation of Arterial Input Function and Tissue Impulse Response in DCE-MRI
  • Single-Channel Blind Estimation of Arterial Input Function and Tissue Impulse Response in DCE-MRI (en)
skos:prefLabel
  • Single-Channel Blind Estimation of Arterial Input Function and Tissue Impulse Response in DCE-MRI
  • Single-Channel Blind Estimation of Arterial Input Function and Tissue Impulse Response in DCE-MRI (en)
skos:notation
  • RIV/68081731:_____/12:00385359!RIV13-AV0-68081731
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GA102/09/1690), S
http://linked.open...iv/cisloPeriodika
  • 4
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 168133
http://linked.open...ai/riv/idVysledku
  • RIV/68081731:_____/12:00385359
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • arterial input function (AIF); blind deconvolution; dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI); multichannel; perfusion; single channel (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [FEC69E116F03]
http://linked.open...i/riv/nazevZdroje
  • IEEE Transactions on Biomedical Engineering
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 59
http://linked.open...iv/tvurceVysledku
  • Bartoš, M.
  • Jiřík, Radovan
  • Rygh, C. B.
  • Taxt, T.
  • Andersen, E.
  • Curry, F. R.
  • Grüner, R.
  • Reed, R. K.
http://linked.open...ain/vavai/riv/wos
  • 000302175300013
issn
  • 0018-9294
number of pages
http://bibframe.org/vocab/doi
  • 10.1109/TBME.2011.2182195
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 36 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software