About: Effect of sample tilt on PEEM resolution     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • In electron microscopy design, the systems are usually assumed to be perfectly aligned or that possible small imperfections can be eliminated by simple multipole correctors (centering deflectors, stigmators) without loss of resolution. However, in some cases, like in the cathode lens between the sample and the objective lens in the photoemission electron microscope, even a small imperfection can impair the resolution significantly. Because of the strong field between the sample and the objective lens, even a small tilt of the sample generates a parasitic dipole field, which decreases resolution and causes image deformations. We present a simulation of the influence of a small sample tilt on the system resolution based on modern computational methods that enable simulation of the whole system including the parasitic fields, proper setting of centering deflectors and stigmators. The resolution is determined by simulating the point spread function and finding the size of its significant part. The procedure is shown on realistic data from the literature. We found out that the resolution becomes worse mainly in the direction of the parasitic dipole field.
  • In electron microscopy design, the systems are usually assumed to be perfectly aligned or that possible small imperfections can be eliminated by simple multipole correctors (centering deflectors, stigmators) without loss of resolution. However, in some cases, like in the cathode lens between the sample and the objective lens in the photoemission electron microscope, even a small imperfection can impair the resolution significantly. Because of the strong field between the sample and the objective lens, even a small tilt of the sample generates a parasitic dipole field, which decreases resolution and causes image deformations. We present a simulation of the influence of a small sample tilt on the system resolution based on modern computational methods that enable simulation of the whole system including the parasitic fields, proper setting of centering deflectors and stigmators. The resolution is determined by simulating the point spread function and finding the size of its significant part. The procedure is shown on realistic data from the literature. We found out that the resolution becomes worse mainly in the direction of the parasitic dipole field. (en)
Title
  • Effect of sample tilt on PEEM resolution
  • Effect of sample tilt on PEEM resolution (en)
skos:prefLabel
  • Effect of sample tilt on PEEM resolution
  • Effect of sample tilt on PEEM resolution (en)
skos:notation
  • RIV/68081731:_____/12:00385323!RIV13-AV0-68081731
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(IAA100650805)
http://linked.open...iv/cisloPeriodika
  • S1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 133235
http://linked.open...ai/riv/idVysledku
  • RIV/68081731:_____/12:00385323
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • PEEM; LEEM; Aberrations; Misalignment; Sample tilt; Point spread function; Resolution (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [AA33DF279070]
http://linked.open...i/riv/nazevZdroje
  • Ultramicroscopy
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 119
http://linked.open...iv/tvurceVysledku
  • Oral, Martin
  • Radlička, Tomáš
  • Lencová, B.
http://linked.open...ain/vavai/riv/wos
  • 000308079200008
issn
  • 0304-3991
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.ultramic.2011.11.011
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 107 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software