  • The paper deals with the question of how to obtain an accurate density distribution in a cross section of a slurry pipe using a gamma-ray radiometric device adapted for tomography purposes. New radiometric devices at Institute of Hydrodynamics in Prague are presented and basic principles of a measuring method are given. A scatter of a gamma-ray beam and errors in beam-position reading are identified as major factors reducing accuracy of results, particularly in the region near the pipe wall. A numerical simulation was performed to investigate a relation between a standard deviation of the evaluated density and the total measuring time. Only qualitative conclusions can be drawn from the simulation results, however the results demonstrate clearly an importance of a suitable geometrical setup for an experiment using the tomography method.
  • The paper deals with the question of how to obtain an accurate density distribution in a cross section of a slurry pipe using a gamma-ray radiometric device adapted for tomography purposes. New radiometric devices at Institute of Hydrodynamics in Prague are presented and basic principles of a measuring method are given. A scatter of a gamma-ray beam and errors in beam-position reading are identified as major factors reducing accuracy of results, particularly in the region near the pipe wall. A numerical simulation was performed to investigate a relation between a standard deviation of the evaluated density and the total measuring time. Only qualitative conclusions can be drawn from the simulation results, however the results demonstrate clearly an importance of a suitable geometrical setup for an experiment using the tomography method. (en)
Title
  • Accuracy study of computer tomography method for radiometric density meter
  • Accuracy study of computer tomography method for radiometric density meter (en)
skos:prefLabel
  • Accuracy study of computer tomography method for radiometric density meter
  • Accuracy study of computer tomography method for radiometric density meter (en)
skos:notation
  • RIV/67985874:_____/11:00364062!RIV12-AV0-67985874
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA103/09/0383), Z(AV0Z20600510)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 184420
http://linked.open...ai/riv/idVysledku
  • RIV/67985874:_____/11:00364062
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • gamma-ray measurement; slurry flow; concentration distribution (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [EA568F44F091]
http://linked.open...v/mistoKonaniAkce
  • Wroclaw
http://linked.open...i/riv/mistoVydani
  • Wroclaw
http://linked.open...i/riv/nazevZdroje
  • 15th International Conference on Transport and Sedimentation of Solid Particles
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Krupička, Jan
  • Matoušek, Václav
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • Wroclaw University of Environmental and Life Sciences
https://schema.org/isbn
  • 978-83-62633-16-6
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software