| - Various stationary phases were tested for the analysis of complex mixture of triacylglycerols (TGs) in blackcurrant oil using non-aqueous reversed-phase system with acetonitrile–2-propanol mobile phase. Compared to conventional C18 column, retention times of TGs were reduced almost 10 times without the loss of the chromatographic resolution using ultra high-performance liquid chromatography. The separation on C30 column shows an unusual phenomenon, the dependence of the retention order of TGs on the column temperature. The sample throughput on the commercial monolithic column modified with C18 was increased at cost of low resolution.
- Various stationary phases were tested for the analysis of complex mixture of triacylglycerols (TGs) in blackcurrant oil using non-aqueous reversed-phase system with acetonitrile–2-propanol mobile phase. Compared to conventional C18 column, retention times of TGs were reduced almost 10 times without the loss of the chromatographic resolution using ultra high-performance liquid chromatography. The separation on C30 column shows an unusual phenomenon, the dependence of the retention order of TGs on the column temperature. The sample throughput on the commercial monolithic column modified with C18 was increased at cost of low resolution. (en)
|
Title
| - Comparison of Various Types of Stationary Phases in Non-Aqueous Reversed-Phase High-Performance Liquid Chromatography–Mass Spectrometry of Glycerolipids in Blackcurrant Oil and Its Enzymatic Hydrolysis Mixture
- Comparison of Various Types of Stationary Phases in Non-Aqueous Reversed-Phase High-Performance Liquid Chromatography–Mass Spectrometry of Glycerolipids in Blackcurrant Oil and Its Enzymatic Hydrolysis Mixture (en)
|
skos:prefLabel
| - Comparison of Various Types of Stationary Phases in Non-Aqueous Reversed-Phase High-Performance Liquid Chromatography–Mass Spectrometry of Glycerolipids in Blackcurrant Oil and Its Enzymatic Hydrolysis Mixture
- Comparison of Various Types of Stationary Phases in Non-Aqueous Reversed-Phase High-Performance Liquid Chromatography–Mass Spectrometry of Glycerolipids in Blackcurrant Oil and Its Enzymatic Hydrolysis Mixture (en)
|
skos:notation
| - RIV/67985858:_____/09:00337499!RIV10-AV0-67985858
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(GA203/09/0139), P(GP203/09/P249), Z(AV0Z40720504), Z(MSM0021627502)
|
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/67985858:_____/09:00337499
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - ultra high-performance liquid chromatography; C30 stationary phase; triacylglycerols (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Journal of Chromatography A
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Holčapek, M.
- Lísa, M.
- Sovová, Helena
|
http://linked.open...ain/vavai/riv/wos
| |
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |