| - A new apparatus suitable for accurate measurement of extremely low aqueous solubilities of polynuclear aromatic hydrocarbons (PAH) employing the generator column technique of May et al. has been constructed. In our implementation, the generator column, the extractor column, and the analytical HPLC column are linked by means of a system of three rotary HPLC valves that provide for a complete and convenient control of the measurement sequence including the introduction of calibration samples.
- A new apparatus suitable for accurate measurement of extremely low aqueous solubilities of polynuclear aromatic hydrocarbons (PAH) employing the generator column technique of May et al. has been constructed. In our implementation, the generator column, the extractor column, and the analytical HPLC column are linked by means of a system of three rotary HPLC valves that provide for a complete and convenient control of the measurement sequence including the introduction of calibration samples. (en)
- Nová aparatura pro měření rozpustnosti ve vodě extrémně hydrofobních polyaromatických uhlovodíků využívající metodu generátorové kolony byla postavena. V našem uspořádání, generátorová, extrakční a analytická HPLC kolona jsou spojeny pomocí tří šesticestných ventilů tak, že celý experiment (včetně kalibrace) může být řízen pouze jejich přepínáním. Funkčnost aparatury byla důkladně otestována. (cs)
|
Title
| - Temperature Dependence of Aqueous Solubility of Anthracenes: Accurate Determination by a New Generator Column Apparatus
- Temperature Dependence of Aqueous Solubility of Anthracenes: Accurate Determination by a New Generator Column Apparatus (en)
- Teplotní závislost rozpustnosti ve vodě pro anthraceny: přesné stanovení pomocí nové aparatury metody generátorové kolony (cs)
|
skos:prefLabel
| - Temperature Dependence of Aqueous Solubility of Anthracenes: Accurate Determination by a New Generator Column Apparatus
- Temperature Dependence of Aqueous Solubility of Anthracenes: Accurate Determination by a New Generator Column Apparatus (en)
- Teplotní závislost rozpustnosti ve vodě pro anthraceny: přesné stanovení pomocí nové aparatury metody generátorové kolony (cs)
|
skos:notation
| - RIV/67985858:_____/03:00028581!RIV06-AV0-67985858
|
http://linked.open.../vavai/riv/strany
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - Z(AV0Z4072921), Z(MSM 223400008)
|
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/67985858:_____/03:00028581
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - solubility; generator column; aromatic hydrocarbons (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Dohnal, V.
- Dohányosová, Pavla
- Fenclová, D.
|
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |