  • Nezralí potkani byli vystaveni statickému magnetickému poli a v dospělosti jim byla testována funkční lateralita cholinergího neurotransmiterového systému. Byla nalezena snížená aktivita v pravém hipokampu zvířat po expozici negativnímu poli. In vitro test s magnetickými nanočásticemi potvrdil rozdíly mezi pravým a levým hipokampem. (cs)
  • Immature animals were exposed to a static magnetic field and a functional laterality of cholinergic neurotransmitter system was evaluated in their adulthood. The decreased activity was found in the right hippocampus in animals exposed to a negative field. In vitro test with magnetic nanoparticles supported differences between the right and left hippocampi.
  • Immature animals were exposed to a static magnetic field and a functional laterality of cholinergic neurotransmitter system was evaluated in their adulthood. The decreased activity was found in the right hippocampus in animals exposed to a negative field. In vitro test with magnetic nanoparticles supported differences between the right and left hippocampi. (en)
Title
  • Exposure of Postnatal Rats to a Static Magnetic Field of 0.14 T Influences Functional Laterality of the Hippocampal High-Affinity Choline Uptake System in Adulthood; In Vitro Test With Magnetic Nanoparticles
  • Expozice postnatálních potkanů statickému magnetickému poli 0.14 T ovlivňuje funkční lateralitu systému vysokoafinitního uptaku cholinu v hipokampu dospělých zvířat; In vitro test s magnetickými nanočásticemi (cs)
  • Exposure of Postnatal Rats to a Static Magnetic Field of 0.14 T Influences Functional Laterality of the Hippocampal High-Affinity Choline Uptake System in Adulthood; In Vitro Test With Magnetic Nanoparticles (en)
skos:prefLabel
  • Exposure of Postnatal Rats to a Static Magnetic Field of 0.14 T Influences Functional Laterality of the Hippocampal High-Affinity Choline Uptake System in Adulthood; In Vitro Test With Magnetic Nanoparticles
  • Expozice postnatálních potkanů statickému magnetickému poli 0.14 T ovlivňuje funkční lateralitu systému vysokoafinitního uptaku cholinu v hipokampu dospělých zvířat; In vitro test s magnetickými nanočásticemi (cs)
  • Exposure of Postnatal Rats to a Static Magnetic Field of 0.14 T Influences Functional Laterality of the Hippocampal High-Affinity Choline Uptake System in Adulthood; In Vitro Test With Magnetic Nanoparticles (en)
skos:notation
  • RIV/67985807:_____/05:00405438!RIV08-MZ0-67985807
http://linked.open.../vavai/riv/strany
  • 253;262
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(NF7576)
http://linked.open...iv/cisloPeriodika
  • 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 521198
http://linked.open...ai/riv/idVysledku
  • RIV/67985807:_____/05:00405438
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • magnetic nanoparticles; choline transport; cholinergic; functional impairment; hippocampus; laterality; magnetoreception; static magnetic field (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [15992C266E52]
http://linked.open...i/riv/nazevZdroje
  • Neurochemical Research
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 30
http://linked.open...iv/tvurceVysledku
  • Zach, P.
  • Čermák, M.
  • Klaschka, Jan
  • Krištofiková, Z.
  • Benešová, O.
issn
  • 0364-3190
number of pages
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 110 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software