About: Technologie Vital Monitor II     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Mobile system for heart and respiratory rate monitoring with a new type of sensor arrangement. Key elements of the technology: The system monitors heart and respiratory rate with the accuracy required by the physicians. The system is ready for full operation in a hospital environment. The system is fully mobile. Know-how contains new unique mathematical method how to extract the information on the patient's vital functions from the data measured by transducers embedded in the hospital beds frame and their software implementation. The system is based on the technology Vital Monitor, but it has extendeed its abilities so much it can be considered a completely new system.The novelty of the technology is based on the significant increase of the outputs beneficial for the physicians from the standard transducers of the bed. Mathematical method was designed on the results of the data analysis from hospitals and implemented on fully mobile hardware. (en)
  • Mobilní systém pro monitorování tepové a dechové frekvence s novým typem a uspořádáním senzorů. Klíčové prvky technologie: Systém monitoruje tepovou a dechovou frekvenci s přesností požadovanou lékaři. Systém je připraven pro plný provoz v nemocničním prostředí. Systém je přenositelný na libovolné lůžko. Know-how obsahuje nové unikátní matematické postupy, jak z dat naměřených senzory zabudovanými v rámu nemocničního lůžka společnosti Linet zcela bezkontaktně získávat informace o životních funkcích pacienta a jejich softwarovou implementaci. Systém navazuje na ověřenou techologii Vital Monitor, ovšem její schopnosti překonal natolik, že ho lze považovat za úplně nový systém. Novost technologie spočívá v podstatném rozšíření výstupů užitečných pro lékaře ze stávajících senzorů standardně umísťovaných do lůžek. Matematická metoda byla vyvinuta na základě analýzy dat z nemocnic a implementována na plně přenositelný HW.
  • Mobilní systém pro monitorování tepové a dechové frekvence s novým typem a uspořádáním senzorů. Klíčové prvky technologie: Systém monitoruje tepovou a dechovou frekvenci s přesností požadovanou lékaři. Systém je připraven pro plný provoz v nemocničním prostředí. Systém je přenositelný na libovolné lůžko. Know-how obsahuje nové unikátní matematické postupy, jak z dat naměřených senzory zabudovanými v rámu nemocničního lůžka společnosti Linet zcela bezkontaktně získávat informace o životních funkcích pacienta a jejich softwarovou implementaci. Systém navazuje na ověřenou techologii Vital Monitor, ovšem její schopnosti překonal natolik, že ho lze považovat za úplně nový systém. Novost technologie spočívá v podstatném rozšíření výstupů užitečných pro lékaře ze stávajících senzorů standardně umísťovaných do lůžek. Matematická metoda byla vyvinuta na základě analýzy dat z nemocnic a implementována na plně přenositelný HW. (cs)
Title
  • Technologie Vital Monitor II
  • Technologie Vital Monitor II (cs)
  • Technology Vital Monitor II (en)
skos:prefLabel
  • Technologie Vital Monitor II
  • Technologie Vital Monitor II (cs)
  • Technology Vital Monitor II (en)
skos:notation
  • RIV/62690094:18470/14:50002452!RIV15-MSM-18470___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • N
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...onomickeParametry
  • nárůst ceny průměrně vybaveného lůžka o 3-5%
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 49592
http://linked.open...ai/riv/idVysledku
  • RIV/62690094:18470/14:50002452
http://linked.open...terniIdentifikace
  • Vital Monitor II
http://linked.open...riv/jazykVysledku
http://linked.open...vai/riv/kategorie
http://linked.open.../riv/klicovaSlova
  • vital functions; data analysis (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [C7F22CAE7EF5]
http://linked.open.../licencniPoplatek
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...echnickeParametry
  • Funkční systém implementovaný do inteligentního lůžka společnosti Linet monitorující bezkontaktně vitální funkce. Protokoly o testování k nahlédnutí u předkladatele i vlastníka. Využití dosaženého výsledku řeší %22Smlouva o spolupráci při řešení programového projektu Systém pro diagnostiku kardiovaskulární dynamiky%22 mezi Univerzitou Hradec Králové a Linet spol. s r. o., IČO 00507814, uzavřená v roce 2008. Výsledek lze ověřit v Linet spol. s r. o. Podrobnosti řeší dílčí smlouva o dílo se společností Linet, spol. s r. o., č. SML/0411/0018/11 na částku 500 400,00 Kč bez DPH.
http://linked.open...iv/tvurceVysledku
  • Kříž, Jan
  • Studnička, Filip
  • Jezbera, Daniel
  • Šeba, Petr
  • Lipovský, Jiří
http://linked.open...avai/riv/vlastnik
http://linked.open...itiJinymSubjektem
http://localhost/t...ganizacniJednotka
  • 18470
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software