About: Determination of Fluoride in Plant Material using Microwave Induced Oxygen Combustion     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Fluorine is essential in human and/or animal nutrition, thus it is important to know its concentration in a diet. One of the important sources of fluorine for humans is tea, containing relatively high amounts of this trace element. A method for fluoride determination in various kinds of tea using microwave supported sample preparation in a high pressure oxygen atmosphere followed by potentiometry with a fluoride ion-selective electrode were described. The parameters of the microwave device for such combustion procedure were checked and optimised in order to find settings ensuring complete sample combustion and/or absorption of the analyte in the absorption solution. For the ion-selective electrode measurement, the technique of standard addition was chosen. The Nernstian slope of the fluoride ion-selective electrode was measured and calculated in the concentration range in which the potential of samples occurred. Concentrations of fluorides in tea in the range from 24.5 mg/kg to 254.5 mg/kg were found. In order to check the accuracy of the method certified reference materials were used. The precision expressed as the relative standard deviation ranged from 3.7% to 15.9%. The method is fast, accurate and reliable for this kind of analysis
  • Fluorine is essential in human and/or animal nutrition, thus it is important to know its concentration in a diet. One of the important sources of fluorine for humans is tea, containing relatively high amounts of this trace element. A method for fluoride determination in various kinds of tea using microwave supported sample preparation in a high pressure oxygen atmosphere followed by potentiometry with a fluoride ion-selective electrode were described. The parameters of the microwave device for such combustion procedure were checked and optimised in order to find settings ensuring complete sample combustion and/or absorption of the analyte in the absorption solution. For the ion-selective electrode measurement, the technique of standard addition was chosen. The Nernstian slope of the fluoride ion-selective electrode was measured and calculated in the concentration range in which the potential of samples occurred. Concentrations of fluorides in tea in the range from 24.5 mg/kg to 254.5 mg/kg were found. In order to check the accuracy of the method certified reference materials were used. The precision expressed as the relative standard deviation ranged from 3.7% to 15.9%. The method is fast, accurate and reliable for this kind of analysis (en)
Title
  • Determination of Fluoride in Plant Material using Microwave Induced Oxygen Combustion
  • Determination of Fluoride in Plant Material using Microwave Induced Oxygen Combustion (en)
skos:prefLabel
  • Determination of Fluoride in Plant Material using Microwave Induced Oxygen Combustion
  • Determination of Fluoride in Plant Material using Microwave Induced Oxygen Combustion (en)
skos:notation
  • RIV/62157124:16270/12:43871184!RIV13-MSM-16270___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM6215712402)
http://linked.open...iv/cisloPeriodika
  • 5
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 130582
http://linked.open...ai/riv/idVysledku
  • RIV/62157124:16270/12:43871184
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • tea; sample preparation; ion-selective electode (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [207643EF51FC]
http://linked.open...i/riv/nazevZdroje
  • Czech Journal of Food Sciences
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 30
http://linked.open...iv/tvurceVysledku
  • Bednář, Jiří
  • Šucman, Emanuel
http://linked.open...ain/vavai/riv/wos
  • 000307490900006
http://linked.open...n/vavai/riv/zamer
issn
  • 1212-1800
number of pages
http://localhost/t...ganizacniJednotka
  • 16270
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software