About: Basic values of M-mode echocardiographic parameters of the left ventricle in outbreed Wistar rats.     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • This paper describes the partial results of an echocardiographic study in sixty outbreed Wistar rats. Animals of parity sex ratio were chosen for the experiment. The animals were grown up during the observation period (the minimum weight was 220 g; the maximum weight was 909 g) and were then sequentially anaesthetised (2-2.5% of isoflurane, 3 l/min O2). The second, fourth and fifth examinations were performed under anaesthesia maintained by intramuscular injections with diazepam (2 mg/kg), xylazine (5 mg/kg) and ketamine (35 mg/kg). Transthoracal examination was done using the SonoSite Titan echo system (SonoSite Ltd.) with a microconvex transducer C11 (8-5 MHz). M-mode (according to the leading-edge method of American Society of Echocardiography) echocardiography data were acquired at the papillary muscle: systolic and diastolic interventricular septum (IVSs, d) and left vetricular posterior wall (LVPWs, d) thickness, systolic and diastolic left ventricular dimension (LVDs, d), aorta (Ao) and left atrium (LA) dimensions. According to standard formulas, the following parameters were obtained: ejection fraction (EF), cardiac output (CO), stroke volume (SV), left ventricle end systolic volume (LVESV), left ventricle end diastolic volume (LVEDV), interventricular septum fractional thickening (IVSFT), left ventricular dimension fraction shortening (LVDFS), and left ventricle posterior wall fraction thickening (LVPWFS). In our study we performed 300 examinations both in male and female Wistar rats of various body weights and calculated regression equations to predict expected normal echocardiographic parameters for rats with arbitrary weights. The rats were examined by an echo scan. The first and third examinations were performed during monoanaesthesia induced by inhalation of isoflurane. Correlations, with one exception (LVDs), were very close, which means that the results of the calculations based on regression equations are very reliable.
  • This paper describes the partial results of an echocardiographic study in sixty outbreed Wistar rats. Animals of parity sex ratio were chosen for the experiment. The animals were grown up during the observation period (the minimum weight was 220 g; the maximum weight was 909 g) and were then sequentially anaesthetised (2-2.5% of isoflurane, 3 l/min O2). The second, fourth and fifth examinations were performed under anaesthesia maintained by intramuscular injections with diazepam (2 mg/kg), xylazine (5 mg/kg) and ketamine (35 mg/kg). Transthoracal examination was done using the SonoSite Titan echo system (SonoSite Ltd.) with a microconvex transducer C11 (8-5 MHz). M-mode (according to the leading-edge method of American Society of Echocardiography) echocardiography data were acquired at the papillary muscle: systolic and diastolic interventricular septum (IVSs, d) and left vetricular posterior wall (LVPWs, d) thickness, systolic and diastolic left ventricular dimension (LVDs, d), aorta (Ao) and left atrium (LA) dimensions. According to standard formulas, the following parameters were obtained: ejection fraction (EF), cardiac output (CO), stroke volume (SV), left ventricle end systolic volume (LVESV), left ventricle end diastolic volume (LVEDV), interventricular septum fractional thickening (IVSFT), left ventricular dimension fraction shortening (LVDFS), and left ventricle posterior wall fraction thickening (LVPWFS). In our study we performed 300 examinations both in male and female Wistar rats of various body weights and calculated regression equations to predict expected normal echocardiographic parameters for rats with arbitrary weights. The rats were examined by an echo scan. The first and third examinations were performed during monoanaesthesia induced by inhalation of isoflurane. Correlations, with one exception (LVDs), were very close, which means that the results of the calculations based on regression equations are very reliable. (en)
Title
  • Basic values of M-mode echocardiographic parameters of the left ventricle in outbreed Wistar rats.
  • Basic values of M-mode echocardiographic parameters of the left ventricle in outbreed Wistar rats. (en)
skos:prefLabel
  • Basic values of M-mode echocardiographic parameters of the left ventricle in outbreed Wistar rats.
  • Basic values of M-mode echocardiographic parameters of the left ventricle in outbreed Wistar rats. (en)
skos:notation
  • RIV/62157124:16170/12:43871654!RIV13-GA0-16170___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(ED1.100/02/0123), P(GP305/08/P297)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 124535
http://linked.open...ai/riv/idVysledku
  • RIV/62157124:16170/12:43871654
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • ketamine; xylazine; diazepam; isoflurane; Wistar; M-mode; echocardiography; rat (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [ED0137E2D773]
http://linked.open...i/riv/nazevZdroje
  • Veterinární medicína
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 57
http://linked.open...iv/tvurceVysledku
  • Svoboda, Petr
  • Uhríková, Ivana
  • Doubek, Jaroslav
  • Scheer, Peter
  • Janečková, Katarína
  • Svěráková, Veronika
http://linked.open...ain/vavai/riv/wos
  • 000301044700003
issn
  • 0375-8427
number of pages
http://localhost/t...ganizacniJednotka
  • 16170
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 47 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software