About: Microfluidic tool coupled with electrochemical assay for detection of lactoferrin isolated by antibody-modified paramagnetic beads     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Lactoferrin (LF) is approximately 80 kDa iron-binding protein, which is important part of saliva and other body fluids. Due to its ability to bind metal ions, it has many biologically important functions. In this study, a method for the isolation of LF from a biological sample using robotically prepared antibody-modified paramagnetic particles was developed using robotic pipetting station. The method consisted of the following optimised steps. Protein G was bound on the paramagnetic particles, on which goat antibody (10 microg) was linked. LF was subsequently added to microtitration plate, which had affinity to goat antibody and the interaction lasted for 30 min. We found that the highest signals were obtained using the combination of goat antibody 1:3000, murine antibody 1:5000 and conjugate 1:1500. The resulted product of this reaction was subsequently analysed spectrometrically with detection limit (3 S/N) as 5 ng/mL. In addition, we also determined TMB by stopped flow injection analysis with electrochemical detection. The limit of detection (3 S/N) was estimated as 0.1 microg/mL. To compare spectrometric and electrochemical approach for detection of TMB, calibration range of bead-LF-antibodies complex was prepared and was determined using a least-squares correlation with coefficient R2 higher than 0.95, indicating a very good agreement of the results obtained.
  • Lactoferrin (LF) is approximately 80 kDa iron-binding protein, which is important part of saliva and other body fluids. Due to its ability to bind metal ions, it has many biologically important functions. In this study, a method for the isolation of LF from a biological sample using robotically prepared antibody-modified paramagnetic particles was developed using robotic pipetting station. The method consisted of the following optimised steps. Protein G was bound on the paramagnetic particles, on which goat antibody (10 microg) was linked. LF was subsequently added to microtitration plate, which had affinity to goat antibody and the interaction lasted for 30 min. We found that the highest signals were obtained using the combination of goat antibody 1:3000, murine antibody 1:5000 and conjugate 1:1500. The resulted product of this reaction was subsequently analysed spectrometrically with detection limit (3 S/N) as 5 ng/mL. In addition, we also determined TMB by stopped flow injection analysis with electrochemical detection. The limit of detection (3 S/N) was estimated as 0.1 microg/mL. To compare spectrometric and electrochemical approach for detection of TMB, calibration range of bead-LF-antibodies complex was prepared and was determined using a least-squares correlation with coefficient R2 higher than 0.95, indicating a very good agreement of the results obtained. (en)
Title
  • Microfluidic tool coupled with electrochemical assay for detection of lactoferrin isolated by antibody-modified paramagnetic beads
  • Microfluidic tool coupled with electrochemical assay for detection of lactoferrin isolated by antibody-modified paramagnetic beads (en)
skos:prefLabel
  • Microfluidic tool coupled with electrochemical assay for detection of lactoferrin isolated by antibody-modified paramagnetic beads
  • Microfluidic tool coupled with electrochemical assay for detection of lactoferrin isolated by antibody-modified paramagnetic beads (en)
skos:notation
  • RIV/62156489:43210/13:00213585!RIV14-MSM-43210___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • O
http://linked.open...iv/cisloPeriodika
  • 14
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 88178
http://linked.open...ai/riv/idVysledku
  • RIV/62156489:43210/13:00213585
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Microfluidic tool; lactoferrin; paramagnetic particles (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [7F099F7D1CF6]
http://linked.open...i/riv/nazevZdroje
  • Electrophoresis
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 34
http://linked.open...iv/tvurceVysledku
  • Adam, Vojtěch
  • Fialová, Dana
  • Kizek, René
  • Křížková, Soňa
  • Skaličková, Sylvie
  • Zítka, Ondřej
http://linked.open...ain/vavai/riv/wos
  • 327662400022
issn
  • 0173-0835
number of pages
http://bibframe.org/vocab/doi
  • 10.1002/elps.201200631
http://localhost/t...ganizacniJednotka
  • 43210
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 90 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software