About: Evalution of the efficiency of selected wastewater treatment plant     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • This paper is focused on primary, secondary, and total effi ciency evaluation of the wastewater treatment process for chosen small wastewater treatment plant (WWTP) located near the Moravian Karst. Eight wastewater samples were taken during one year in three sampling profi les of WWTP: biochemical oxygen demand (BOD), chemical oxygen demand (COD), suspended solids (SS), pH, ammonia nitrogen (N-NH4), nitrite nitrogen (N-NO2), nitrate nitrogen (N-NO3), inorganic nitrogen (Ninorg), total phosphorus (Ptotal). Treatment effi ciency by reduction was calculated for all laboratory analyzed indicators and average values were determined for the whole period. Calculated treatment effi ciency of indicators BOD, COD and suspended solids was compared with the permissible minimum treatment effi ciency of discharged waste water by Government Regulation No. 61/2003 Coll., for the WWTP from 500 to 2 000 PE. Permissible minimum treatment effi ciency is not legislatively determined for the primary and secondary level. The results of the work will be used especially to compare results with other similar works. Analyzed values of parameters BOD, COD, suspended solids, N-NH4 at the outfl ow from wastewater treatment plant were compared with the permissible maximum values at the outfl ow of the WWTP which the municipality has an obligation to respect according to the decision issued by the District Environment Authority.
  • This paper is focused on primary, secondary, and total effi ciency evaluation of the wastewater treatment process for chosen small wastewater treatment plant (WWTP) located near the Moravian Karst. Eight wastewater samples were taken during one year in three sampling profi les of WWTP: biochemical oxygen demand (BOD), chemical oxygen demand (COD), suspended solids (SS), pH, ammonia nitrogen (N-NH4), nitrite nitrogen (N-NO2), nitrate nitrogen (N-NO3), inorganic nitrogen (Ninorg), total phosphorus (Ptotal). Treatment effi ciency by reduction was calculated for all laboratory analyzed indicators and average values were determined for the whole period. Calculated treatment effi ciency of indicators BOD, COD and suspended solids was compared with the permissible minimum treatment effi ciency of discharged waste water by Government Regulation No. 61/2003 Coll., for the WWTP from 500 to 2 000 PE. Permissible minimum treatment effi ciency is not legislatively determined for the primary and secondary level. The results of the work will be used especially to compare results with other similar works. Analyzed values of parameters BOD, COD, suspended solids, N-NH4 at the outfl ow from wastewater treatment plant were compared with the permissible maximum values at the outfl ow of the WWTP which the municipality has an obligation to respect according to the decision issued by the District Environment Authority. (en)
Title
  • Evalution of the efficiency of selected wastewater treatment plant
  • Evalution of the efficiency of selected wastewater treatment plant (en)
skos:prefLabel
  • Evalution of the efficiency of selected wastewater treatment plant
  • Evalution of the efficiency of selected wastewater treatment plant (en)
skos:notation
  • RIV/62156489:43210/12:00183726!RIV13-MSM-43210___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 135243
http://linked.open...ai/riv/idVysledku
  • RIV/62156489:43210/12:00183726
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • wastewater; wastewater treatment plant; treatment efficiency; secondary treatment; primary treatment; pollution indicators (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [EB7BC20E5E41]
http://linked.open...i/riv/nazevZdroje
  • Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • LX
http://linked.open...iv/tvurceVysledku
  • Oppeltová, Petra
  • Vítěz, Tomáš
  • Ševčíková, Jana
issn
  • 1211-8516
number of pages
http://localhost/t...ganizacniJednotka
  • 43210
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software