AttributesValues
rdf:type
Description
  • A high-performance liquid chromatographic/mass spectrometric method (HPLC/MS) has been developed to determine both 4-methylimidazole (4MeI) and 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl)imidazole (THI) in one run. Among three sorbents tested, the best peak shape of 4MeI was achieved on a reversed phase MetaChem Polaris C18-A at pH 9.5. The sensitivity and the range of UV detection at 215 and 290 nm for 4MeI and THI, respectively, were compared to the parameters achieved by the electrospray ionization mass spectrometric (ESI/MS) detection in the presence of 5 mmol.L-1 ammonium hydroxide using selected ion-monitoring (SIM) mode. The on-column limits of detection were 0.147 ng of 4MeI and 0.084 ng of THI using UV detection and 1 pg of 4MeI and 3 pg of THI using ESI/MS detection, respectively. The effect of both ammonium ion concentration and energy of fragmentation on 4MeI and THI ionization is discussed. The method could be applied for a fast and sensitive determination of 4MeI and THI in different biologic
  • A high-performance liquid chromatographic/mass spectrometric method (HPLC/MS) has been developed to determine both 4-methylimidazole (4MeI) and 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl)imidazole (THI) in one run. Among three sorbents tested, the best peak shape of 4MeI was achieved on a reversed phase MetaChem Polaris C18-A at pH 9.5. The sensitivity and the range of UV detection at 215 and 290 nm for 4MeI and THI, respectively, were compared to the parameters achieved by the electrospray ionization mass spectrometric (ESI/MS) detection in the presence of 5 mmol.L-1 ammonium hydroxide using selected ion-monitoring (SIM) mode. The on-column limits of detection were 0.147 ng of 4MeI and 0.084 ng of THI using UV detection and 1 pg of 4MeI and 3 pg of THI using ESI/MS detection, respectively. The effect of both ammonium ion concentration and energy of fragmentation on 4MeI and THI ionization is discussed. The method could be applied for a fast and sensitive determination of 4MeI and THI in different biologic (en)
  • A high-performance liquid chromatographic/mass spectrometric method (HPLC/MS) has been developed to determine both 4-methylimidazole (4MeI) and 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl)imidazole (THI) in one run. Among three sorbents tested, the best peak shape of 4MeI was achieved on a reversed phase MetaChem Polaris C18-A at pH 9.5. The sensitivity and the range of UV detection at 215 and 290 nm for 4MeI and THI, respectively, were compared to the parameters achieved by the electrospray ionization mass spectrometric (ESI/MS) detection in the presence of 5 mmol.L-1 ammonium hydroxide using selected ion-monitoring (SIM) mode. The on-column limits of detection were 0.147 ng of 4MeI and 0.084 ng of THI using UV detection and 1 pg of 4MeI and 3 pg of THI using ESI/MS detection, respectively. The effect of both ammonium ion concentration and energy of fragmentation on 4MeI and THI ionization is discussed. The method could be applied for a fast and sensitive determination of 4MeI and THI in different biologic (cs)
Title
  • A Reversed-Phase High-Performance Liquid Chromatographic/Mass Spectrometric (RP-HPLC/MS-SIM) Method for Separation of 4-methylimidazole and 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl)imidazole at pg levels
  • A Reversed-Phase High-Performance Liquid Chromatographic/Mass Spectrometric (RP-HPLC/MS-SIM) Method for Separation of 4-methylimidazole and 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl)imidazole at pg levels (en)
  • RP HPLC/MS stanovení THI a 4MeI (cs)
skos:prefLabel
  • A Reversed-Phase High-Performance Liquid Chromatographic/Mass Spectrometric (RP-HPLC/MS-SIM) Method for Separation of 4-methylimidazole and 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl)imidazole at pg levels
  • A Reversed-Phase High-Performance Liquid Chromatographic/Mass Spectrometric (RP-HPLC/MS-SIM) Method for Separation of 4-methylimidazole and 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl)imidazole at pg levels (en)
  • RP HPLC/MS stanovení THI a 4MeI (cs)
skos:notation
  • RIV/62156489:43210/03:00000995!RIV06-MSM-43210___
http://linked.open.../vavai/riv/strany
  • 49;58
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM 432100001)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 597114
http://linked.open...ai/riv/idVysledku
  • RIV/62156489:43210/03:00000995
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • HPLC; imidazoles; neurotoxins (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [9758BECFCD25]
http://linked.open...i/riv/nazevZdroje
  • Analytica Chimica Acta
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 477
http://linked.open...iv/tvurceVysledku
  • Kubáň, Vlastimil
  • Klejdus, Bořivoj
  • Moravcová, Jitka
http://linked.open...n/vavai/riv/zamer
issn
  • 0003-2670
number of pages
http://localhost/t...ganizacniJednotka
  • 43210
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software