About: Physical and technical principles of the diagnostic system DTP-2 used for diagnostics of posture and deformity of the spine     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Fyzikální a technický princip diagnostického systému DTP-2 pro diagnostiku držení těla a deformit páteře. (cs)
  • There is a need to diagnose a particular deformity of the spine as indicated by a noticable change and deviation of posture. The newly developed diagnostic system DTP-2 can perform quick diagnostics without using an x-ray apparatus. A physical principle of the system is the scanning of points (acromions, spinous protuberants, upper back spinas) in space by a pantographic mechanism with accurate rotary encoders. Electrical output from the encoders is preprocessed in an electronic evaluation unit, consisting of microprocessors, and then transmitted into a PC. Special software can calculate the position of the points in Cartesian coordinates as distances from the ideal vertical axis. The position of points can be displayed in a table or on graphs. Both the 2D graph (in the frontal and sagittal planes) and the 3D graph (in perspective projection) are possible. The curvature and deformity of the spine can be evaluated from numerical and graphical output. The measured data and personal data can be stored in
  • There is a need to diagnose a particular deformity of the spine as indicated by a noticable change and deviation of posture. The newly developed diagnostic system DTP-2 can perform quick diagnostics without using an x-ray apparatus. A physical principle of the system is the scanning of points (acromions, spinous protuberants, upper back spinas) in space by a pantographic mechanism with accurate rotary encoders. Electrical output from the encoders is preprocessed in an electronic evaluation unit, consisting of microprocessors, and then transmitted into a PC. Special software can calculate the position of the points in Cartesian coordinates as distances from the ideal vertical axis. The position of points can be displayed in a table or on graphs. Both the 2D graph (in the frontal and sagittal planes) and the 3D graph (in perspective projection) are possible. The curvature and deformity of the spine can be evaluated from numerical and graphical output. The measured data and personal data can be stored in (en)
Title
  • Fyzikální a technický princip diagnostického systému DTP-2 pro diagnostiku držení těla a deformit páteře (cs)
  • Physical and technical principles of the diagnostic system DTP-2 used for diagnostics of posture and deformity of the spine
  • Physical and technical principles of the diagnostic system DTP-2 used for diagnostics of posture and deformity of the spine (en)
skos:prefLabel
  • Fyzikální a technický princip diagnostického systému DTP-2 pro diagnostiku držení těla a deformit páteře (cs)
  • Physical and technical principles of the diagnostic system DTP-2 used for diagnostics of posture and deformity of the spine
  • Physical and technical principles of the diagnostic system DTP-2 used for diagnostics of posture and deformity of the spine (en)
skos:notation
  • RIV/61989592:15510/04:00001255!RIV/2005/MSM/155105/N
http://linked.open.../vavai/riv/strany
  • 112-115
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM 155100016)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 579489
http://linked.open...ai/riv/idVysledku
  • RIV/61989592:15510/04:00001255
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • position sensor;noninvasive diagnostics;posture (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [51B65C74E5B8]
http://linked.open...i/riv/mistoVydani
  • Olomouc
http://linked.open...i/riv/nazevZdroje
  • Movement and health : 3rd international conference
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Novotný, Jiří
  • Krejčí, Jakub
  • Salinger, Jiří
  • Štěpaník, Petr
  • Kolisko, Petr
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • Univerzita Palackého v Olomouci
https://schema.org/isbn
  • 80-244-0831-7
http://localhost/t...ganizacniJednotka
  • 15510
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software