About: Determination of creatinine in urine by tandem mass spectrometry     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Background. Electrospray tandem mass spectrometry (TMS) is a very powerful tool that enables one to perform high sample throughput analysis. This paper describes a method to determine creatinine in urine by tandem mass spectrometry with direct sample infusion into an ion source. Methods. Samples (50 mul) were diluted with internal standard (IS) (450 mul of 0.667 mmol/l deuterated creatinine). Diluted samples were introduced into mass spectrometer with no prior pretreatment and after purification on ion-exchange 96-column cartridge. Tandem mass spectrometry analyses were performed in selected reaction monitoring mode. Creatinine and creatinine-d(3) were monitored using precursor and product ion settings (m/z 114 to 86 and m/z 117 to 89, respectively). The time of an analysis was 3.015 min. Both TMS methods were compared mutually and with the results obtained by enzymatic and Jaffe method. Results. Linearity was obtained in the range 0.06-60 mmol/l. Detection limit was 0.2 mumol/l and recoveries were
  • Background. Electrospray tandem mass spectrometry (TMS) is a very powerful tool that enables one to perform high sample throughput analysis. This paper describes a method to determine creatinine in urine by tandem mass spectrometry with direct sample infusion into an ion source. Methods. Samples (50 mul) were diluted with internal standard (IS) (450 mul of 0.667 mmol/l deuterated creatinine). Diluted samples were introduced into mass spectrometer with no prior pretreatment and after purification on ion-exchange 96-column cartridge. Tandem mass spectrometry analyses were performed in selected reaction monitoring mode. Creatinine and creatinine-d(3) were monitored using precursor and product ion settings (m/z 114 to 86 and m/z 117 to 89, respectively). The time of an analysis was 3.015 min. Both TMS methods were compared mutually and with the results obtained by enzymatic and Jaffe method. Results. Linearity was obtained in the range 0.06-60 mmol/l. Detection limit was 0.2 mumol/l and recoveries were (en)
Title
  • Determination of creatinine in urine by tandem mass spectrometry
  • Determination of creatinine in urine by tandem mass spectrometry (en)
skos:prefLabel
  • Determination of creatinine in urine by tandem mass spectrometry
  • Determination of creatinine in urine by tandem mass spectrometry (en)
skos:notation
  • RIV/61989592:15310/04:00010390!RIV10-MSM-15310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S, Z(MSM 151100006)
http://linked.open...iv/cisloPeriodika
  • 1-2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 560063
http://linked.open...ai/riv/idVysledku
  • RIV/61989592:15310/04:00010390
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • creatinine; tandem mass spectrometry (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [6106963E188D]
http://linked.open...i/riv/nazevZdroje
  • Clinica Chimica Acta
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 350
http://linked.open...iv/tvurceVysledku
  • Chrastina, David
  • Schneiderka, Petr
  • Adam, Tomáš
  • Hušková, Renata
http://linked.open...n/vavai/riv/zamer
issn
  • 0009-8981
number of pages
http://localhost/t...ganizacniJednotka
  • 15310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software